2012
DOI: 10.1016/j.ijepes.2012.03.043
|View full text |Cite
|
Sign up to set email alerts
|

Towards the establishment of maximum PV generation limits due to power quality constraints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
23
0
3

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(27 citation statements)
references
References 34 publications
1
23
0
3
Order By: Relevance
“…Thus, the efficiency and lifespan of solar systems highly depend on the actual radiation field for each specific location. For instance, a high variability in the solar radiation, occurring mainly under broken cloud conditions, increases the fatigue of materials (Patsalides et al 2007;Patsalides et al 2012).…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the efficiency and lifespan of solar systems highly depend on the actual radiation field for each specific location. For instance, a high variability in the solar radiation, occurring mainly under broken cloud conditions, increases the fatigue of materials (Patsalides et al 2007;Patsalides et al 2012).…”
Section: Introductionmentioning
confidence: 99%
“…PV harmonic current emission obviously depends on PV inverter technology and its control strategy. However, the results of harmonic current emission are not completely different for different PV inverters since they all seem to respond to a similar pattern .…”
Section: Harmonics In Pv Output Currentsmentioning
confidence: 92%
“…In addition, this research proposes a method in which the first characterisation (fundamental-frequency PV current) determines the weights of a mixture distribution based on the second characterisation (PV harmonic currents). This method makes it possible to obtain the distribution functions of the PV harmonic currents (absolute magnitude and phase angle) since these currents mainly depend on the PV power output level [5][6][7][8][28][29][30][31][32][33][34]. Furthermore, one of the key points of this harmonic modelling of the PV system models is the fact that it provides the relationship between PV harmonic current emission and background harmonic voltages at a given operating point of the system (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The harmonic impact due to CFLs was studied in [1][2][3]. In [4,5], the effects of residential photovoltaic installations were analyzed. With a high penetration of EV charges, the harmonic distortion is discussed as shown in [6,7].…”
Section: Introductionmentioning
confidence: 99%