2021
DOI: 10.1016/j.resconrec.2020.105283
|View full text |Cite
|
Sign up to set email alerts
|

Towards green thermal power plants with blowdown water reuse and simultaneous biogenic nanostructures recovery from waste

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 56 publications
0
3
0
Order By: Relevance
“…The pellets were washed 2–3 times with PBS of 0.15 M and placed for lyophilization (Allied Frost FD3). The dried microalgal powder was ground and homogenized with KBr at the ratio of 1:100, and the mixture was pressed by a molding machine with a pressure load of 200 kg cm −2 for 5 min [ 38 ]. The fine KBr pellet which consists of dried microalgae pwder was prepared and placed at the deuterated triglycine sulfate (DTGS) detector of Nicolet Is50 (Thermo Scientific) FT-IR spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…The pellets were washed 2–3 times with PBS of 0.15 M and placed for lyophilization (Allied Frost FD3). The dried microalgal powder was ground and homogenized with KBr at the ratio of 1:100, and the mixture was pressed by a molding machine with a pressure load of 200 kg cm −2 for 5 min [ 38 ]. The fine KBr pellet which consists of dried microalgae pwder was prepared and placed at the deuterated triglycine sulfate (DTGS) detector of Nicolet Is50 (Thermo Scientific) FT-IR spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…This method yielded satisfactory results; however, the process could not remove organic matter (3.3 mg/L) [40]. Jain et al (2021) indicated that the removal of silica (reactive and colloidal) using diatom biofilms developed from water generated from cooling towers of thermal power plants may save annually 1485 MLD of fresh water, in addition to the generation of value-added products (biogenic silica) [41]. In a previous study, the water reuse systems were optimized using an advanced control system for RO, in which more than Euro 10,000,000 could be saved per year in large RO facilities (>30.000 m 3 /day) [42].…”
Section: Tertiary Treatment (Tt)mentioning
confidence: 99%
“…The MCT/VS-based reactive dye wastewater arising from UV/H 2 O 2 treatment may be used in up to two dyeing cycles without decreasing the color quality of the dyed cotton [43]. In another study [44], removing silica (reactive and colloidal) using diatom biofilms from the water generated from cooling tower blowdown of thermal power plants resulted in annual savings of 1485 megaliters/day (MLD) of fresh water, in addition to generating value-added products (biogenic silica). Chang et al highlighted that it is feasible to increase the number of cycles for reusing the wastewater generated during the production of conventional polyvinyl alcohol sponge, but not all recycled wastewater, after blending it with fresh reactant solution.…”
Section: Water Reuse In Industrymentioning
confidence: 99%