2000
DOI: 10.1016/s0304-3991(99)00164-3
|View full text |Cite
|
Sign up to set email alerts
|

Topographic and phase-contrast imaging in atomic force microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
55
0
3

Year Published

2001
2001
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 98 publications
(61 citation statements)
references
References 4 publications
3
55
0
3
Order By: Relevance
“…Its color code corresponds to the tapping mode phase signal, which is used to visualize material anisotropies, e.g., variations in sample hardness. [15,16] In our case, brighter regions (harder diamond crystals) are surrounded by a network of dark structures, the comparably softer grain boundaries, built up of amorphous sp 3 and sp 2 carbon. [14] Individual diamond crystallites (10-20 nm) are arranged in larger grains with diameters up to $150 nm.…”
Section: Characteristics Of Ncd-coated Glass Substratesmentioning
confidence: 97%
“…Its color code corresponds to the tapping mode phase signal, which is used to visualize material anisotropies, e.g., variations in sample hardness. [15,16] In our case, brighter regions (harder diamond crystals) are surrounded by a network of dark structures, the comparably softer grain boundaries, built up of amorphous sp 3 and sp 2 carbon. [14] Individual diamond crystallites (10-20 nm) are arranged in larger grains with diameters up to $150 nm.…”
Section: Characteristics Of Ncd-coated Glass Substratesmentioning
confidence: 97%
“…observation of protein molecules compared to conventional AFM imaging, but also provides information of surface properties of the molecules [19,20]. Consequently, phase imaging is emerging as a powerful tool for mapping variations in sample properties with superior details and with no cost in speed or resolution.…”
Section: Introductionmentioning
confidence: 99%
“…Phase images obtained simultaneously with height images give additional information of the microstructure. 20,21 CRM analysis.-Raman analysis was performed for the composite film deposited on the carbon steel as well as reference samples of Mefp-1 and ceria films, respectively. The reference samples were prepared by putting a drop of a concentrated solution of Mefp-1 or ceria onto the carbon steel surface and waiting for the solution to dry out, so that a thick layer of Mefp-1 or ceria was formed on the surface.…”
Section: Qcm With Dissipation (Qcm-d)mentioning
confidence: 99%