2001
DOI: 10.1016/s0015-0282(01)02858-8
|View full text |Cite
|
Sign up to set email alerts
|

Tissue response to the STOP microcoil transcervical permanent contraceptive device: results from a prehysterectomy study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
70
2
7

Year Published

2002
2002
2021
2021

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 162 publications
(79 citation statements)
references
References 10 publications
0
70
2
7
Order By: Relevance
“…Its inner polyethylene terephthalate fibres elicit a benign tissue ingrowth that blocks the fallopian tubes in about 3 months, resulting in permanent tubal occlusion. 1 The fibres are wound around a flexible stainless steel inner coil and are surrounded by a dynamic outer nickel titanium alloy coil (Nitinol) that expands to anchor the device across the uterotubal junction during the time required for the completion of fibrosis. The micro-insert is attached to a guide wire and sheathed by a hydrophilic delivery catheter used only for placement and designed to improve access to the tube.…”
Section: Methodsmentioning
confidence: 99%
“…Its inner polyethylene terephthalate fibres elicit a benign tissue ingrowth that blocks the fallopian tubes in about 3 months, resulting in permanent tubal occlusion. 1 The fibres are wound around a flexible stainless steel inner coil and are surrounded by a dynamic outer nickel titanium alloy coil (Nitinol) that expands to anchor the device across the uterotubal junction during the time required for the completion of fibrosis. The micro-insert is attached to a guide wire and sheathed by a hydrophilic delivery catheter used only for placement and designed to improve access to the tube.…”
Section: Methodsmentioning
confidence: 99%
“…Placement could be achieved in 97%, which is even higher than the overall success rates in the normal population [3,5]. A few small retrospective feasibility studies elucidated the advantage to leave the IUD in place, but their outcomes were also less successful [6,7].…”
Section: Discussionmentioning
confidence: 95%
“…Fibrotic tissue is formed in the proximal tube. This chronic fibrotic reaction will be completed in all patients after 3 months after the placement of the device and will block both tubes in all patients: 96.5% at 3 months and 100% at 6 months [3].…”
Section: Introductionmentioning
confidence: 99%
“…Este método de esterilización permanente ha sido aprobado por la Comunidad Europea (febrero 2001) y por la FDA (noviembre 2002), debido a su demostrada seguridad y efectividad (11,12,(14)(15)(16)(17)(18).…”
Section: Discussionunclassified