2019
DOI: 10.1016/j.ijleo.2019.04.093
|View full text |Cite
|
Sign up to set email alerts
|

Time resolved x-ray image of laser plasma interactions using a dilation framing camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…The temporal resolution of the camera is characterized by short X-ray pulses produced by a laser beam focused on a flat iron target. The fringe raw images are obtained, and the experimental results show that the temporal resolution of the camera is better than 10 ps [ 4 ]. The Rohr J dual-source scanner is interested in the pathological type and clinical distance of severe pneumonia in children.…”
Section: Introductionmentioning
confidence: 99%
“…The temporal resolution of the camera is characterized by short X-ray pulses produced by a laser beam focused on a flat iron target. The fringe raw images are obtained, and the experimental results show that the temporal resolution of the camera is better than 10 ps [ 4 ]. The Rohr J dual-source scanner is interested in the pathological type and clinical distance of severe pneumonia in children.…”
Section: Introductionmentioning
confidence: 99%
“…The sample tube was placed in the vacuum chamber. Furthermore, only its static spatial resolution was required to be measured because the dynamic performance of the reticle only relied on the timing performance of the MCP traveling wave gated reticle unit equipped in the later stage [ 25 , 26 , 27 , 28 ]. Therefore, only the ultraviolet lamp was used as the light source during the test.…”
Section: Test Results and Analysismentioning
confidence: 99%
“…In this paper, a MCP-PMT detector is presented to measure the ultrashort UV laser pulse. To make the experiment easier our standard pulse dilation framing tube is modified by removing the phosphor screen and coupling with a strip line electron collector [12], [14].…”
Section: First Proposed the Technique Formentioning
confidence: 99%
“…The best temporal resolutions were obtained about 110 ps, 450 ps with a smaller and larger active area MCP-PMTs, respectively [9], [10]. In order to improve temporal resolution further, a pulse dilation technique has been used in the fast detectors [11]- [14]. Prosser…”
Section: Introductionmentioning
confidence: 99%