2015
DOI: 10.1088/1367-2630/17/7/075011
|View full text |Cite
|
Sign up to set email alerts
|

Time, entropy generation, and optimization in low-dissipation heat devices

Abstract: We present new results obtained from the Carnot-like low-dissipation model of heat devices when size-and time-constraints are taken into account, in particular those obtained from the total cycle time and the contact times of the working system with the external heat reservoirs. The influence of these constraints and of the characteristic time scale of the model on the entropy generation allows for a clear and unified interpretation of different energetic properties for both heat engines and refrigerators (REs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
54
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(54 citation statements)
references
References 23 publications
0
54
0
Order By: Relevance
“…With decreasing α, the partially optimised power (8) monotonously interpolates between 0 (attained for α = 1, t * i,α = ∞ and ε * α = ε C /(2 + ε C ), note that this process is not reversible even-though the cycle duration diverges) and its maximum, reached for α = α * = 0 [61]. The resulting maximum power and the corresponding duration of the isothermal branches thus read…”
Section: Cop At Maximum Cooling Powermentioning
confidence: 93%
See 2 more Smart Citations
“…With decreasing α, the partially optimised power (8) monotonously interpolates between 0 (attained for α = 1, t * i,α = ∞ and ε * α = ε C /(2 + ε C ), note that this process is not reversible even-though the cycle duration diverges) and its maximum, reached for α = α * = 0 [61]. The resulting maximum power and the corresponding duration of the isothermal branches thus read…”
Section: Cop At Maximum Cooling Powermentioning
confidence: 93%
“…A natural starting point for calculating maximum COP at fixed power is thus determination of P for LD refrigerators, which was done in Ref. [61]. Since peculiarities of the derivation strongly affect qualitative behavior of maximum COP at fixed power, we review it in detail.…”
Section: Cop At Maximum Cooling Powermentioning
confidence: 99%
See 1 more Smart Citation
“…The signs −(+) take into account the direction of the heat fluxes from (toward) the hot (cold) reservoir in such a way that Q c and Q h are positive quantities. Then, the total entropy generation is given by At this point, it is helpful to use the dimensionless variables defined in [40]: α ≡ t c /t, Σ c ≡ Σ c /Σ T and t ≡ (t ∆S)/Σ T , where t = t h + t c and Σ T ≡ Σ h + Σ c . In this way, it is possible to define a characteristic total entropy production per unit time for the LD-model aṡ…”
Section: Correspondence Between the He's Variables Of Both Modelsmentioning
confidence: 99%
“…In particular, the CA-efficiency is recovered in the LD-model under the assumption of symmetric dissipation. Recently, a description of the LD model in terms of characteristic dimensionless variables was proposed in [40][41][42]. From this treatment, it is possible to separate efficiency-power behaviors typical of CA-endoreversible engines as well as irreversible engines according to the imposed time constraints.…”
Section: Introductionmentioning
confidence: 99%