2024
DOI: 10.1109/tia.2020.3008134
|View full text |Cite
|
Sign up to set email alerts
|

Three-Phase Filter-Clamped Transformerless Inverter for Grid-Connected Photovoltaic Systems with Low Leakage Current

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…6. Consistent with exisiting literature, the value of C P V is taken as 400 nF and value of R G is taken as 10 Ω [36]- [39] for grid-connected PV converter. For motor drive application, the values of distributed parasitic capacitances and motor frame resistances are taken from [42] i.e., C g1 = 0.33 nF, R g1 = 100 Ω, C g2 = 1.65 nF, R g2 = 220 Ω.…”
Section: Analysis On CMV and Leakage Current With 240cpwmmentioning
confidence: 99%
See 1 more Smart Citation
“…6. Consistent with exisiting literature, the value of C P V is taken as 400 nF and value of R G is taken as 10 Ω [36]- [39] for grid-connected PV converter. For motor drive application, the values of distributed parasitic capacitances and motor frame resistances are taken from [42] i.e., C g1 = 0.33 nF, R g1 = 100 Ω, C g2 = 1.65 nF, R g2 = 220 Ω.…”
Section: Analysis On CMV and Leakage Current With 240cpwmmentioning
confidence: 99%
“…Value of R G is uncertain, usually around few ohms. Based on thorough literature survey of transformerless grid connected PV inverters, R G is taken as 10 Ω in this study [36]- [39].…”
Section: Introductionmentioning
confidence: 99%
“…For completing the removed leakage current, the CMV should remain constant throughout the inverter operation. Rahimi et al 14 have presented a filter-clamped inverter that was used in TLPV connected to a three-phase. The TLPV inverters were highly well-organized and cost effectual compared with alternatives that rely on HF and LF isolation transformers.…”
Section: Recent Research Work: a Brief Reviewmentioning
confidence: 99%
“…From costs perspective, a structure with less number of elements is usually economical. Recently, different types of FCLs are presented with different features [9]- [11], [27]. Whereas the need for a structure that can limit the fault currents is investigated in literature, a simultaneous voltage sag compensation or harmonics compensation is studied just in few literatures such as [9]- [12].…”
mentioning
confidence: 99%
“…In [8], the voltage sag in the presence of superconducting FCL (SFCL) is investigated. The superconductor based FCLs have a low or no power loss during normal and fault conditions, so they are attractive in industry [26]- [27]. However, in recent years due to the high technology demands and higher costs of the superconductive materials, application of non-superconductor FCLs is recommended [1], [9].…”
mentioning
confidence: 99%