1999
DOI: 10.1097/00006324-199901000-00025
|View full text |Cite
|
Sign up to set email alerts
|

Three Interferometric Methods for Measuring the Thickness of Layers of the Tear Film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
53
0
1

Year Published

2003
2003
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 90 publications
(60 citation statements)
references
References 0 publications
0
53
0
1
Order By: Relevance
“…This difficulty in interpreting LLPs (especially the thinner patterns) and the lack of a huge bank of LLP images for reference purposes has meant that many eye care professionals abandoned this test. Other devices for objectively evaluating lipid layer patterns have been designed, from a sophisticated optical system mounted in the laboratory [15] to a digital DR-1 camera designed to evaluate lipid layer thickness [16]. The main drawback of Tearscope compared to the DR-1 camera is that its LLP images show an iris background.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This difficulty in interpreting LLPs (especially the thinner patterns) and the lack of a huge bank of LLP images for reference purposes has meant that many eye care professionals abandoned this test. Other devices for objectively evaluating lipid layer patterns have been designed, from a sophisticated optical system mounted in the laboratory [15] to a digital DR-1 camera designed to evaluate lipid layer thickness [16]. The main drawback of Tearscope compared to the DR-1 camera is that its LLP images show an iris background.…”
Section: Discussionmentioning
confidence: 99%
“…These drawbacks have led to decrease in the use of this useful technique among clinicians and even withdrawal of the Tearscope from the market. This has led to the development of techniques designed to objectively calculate lipid layer thickness using a sophisticated optic system [15]. Other techniques use an interference camera to assess lipid layer thickness by only analysing interference colours [16].…”
Section: Introductionmentioning
confidence: 99%
“…It is also noticeable that the reflectance curve contrast is generally higher at longer wavelengths, which may attribute to the film thickness uniformity within the measurement spot, since shorter wavelengths are more sensitive to the local film uniformity variation. 27 Starting from the initial film thickness just after a drop of the AT is applied to the time when film thickness is not measurable, Fig. 4 shows the AT film thinning dynamics of the horizontally positioned model eye with and without contact lenses (Bausch& Lomb SofLens, Cooper Vision AVAIRA, and Bausch&Lomb PureVision).…”
Section: Measurements Of At Film On a Model Eye With And Without A Comentioning
confidence: 99%
“…9 This has led to the development of techniques designed to objectively calculate lipid layer thickness using a sophisticated optical system. 10 Other techniques use an interference camera to assess lipid layer thickness by only analyzing interference colors. 11 This study was designed to validate a new method of classifying the lipid layer of the tear film based on assessing both texture and color patterns.…”
mentioning
confidence: 99%