2019
DOI: 10.1016/j.eururo.2019.03.037
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional Elastic Augmented-reality Robot-assisted Radical Prostatectomy Using Hyperaccuracy Three-dimensional Reconstruction Technology: A Step Further in the Identification of Capsular Involvement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
35
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 94 publications
(40 citation statements)
references
References 27 publications
0
35
0
Order By: Relevance
“…The accuracy of the NeuroSAFE technique can be increased by reducing the slice thickness at the postero‐lateral margin to 3 mm (from 5 mm), but we have demonstrated excellent concordance with our current process and so it remains unchanged in the protocol in order to manage resources well with no compromise on detail. The emergence of promising fast digital imaging techniques [28] and the ongoing development of new platforms to incorporate preoperative mpMRI information intra‐operatively via augmented reality also hold considerable promise for future strategies to reduce the risk of PSMs [29].…”
Section: Discussionmentioning
confidence: 99%
“…The accuracy of the NeuroSAFE technique can be increased by reducing the slice thickness at the postero‐lateral margin to 3 mm (from 5 mm), but we have demonstrated excellent concordance with our current process and so it remains unchanged in the protocol in order to manage resources well with no compromise on detail. The emergence of promising fast digital imaging techniques [28] and the ongoing development of new platforms to incorporate preoperative mpMRI information intra‐operatively via augmented reality also hold considerable promise for future strategies to reduce the risk of PSMs [29].…”
Section: Discussionmentioning
confidence: 99%
“…We finally implement a pipeline to map a 3D model to the 2D video stream starting from the output of the segmentation, and compare it with the previous approach-based solely on CV techniques. The former approach was also tested and validated during in-vivo surgery, and the results obtained in the improving of the quality of the biopsy are documented in [ 17 ] and [ 35 ]. This demonstrated that the post prostatectomy biopsy’s precision increases with the application of our general approach.…”
Section: Discussionmentioning
confidence: 99%
“…Porpiglia et al recently published their pioneering work on three-dimensional elastic augmented reality when performing RALRP (36). These virtual models are constructed using images from high-resolution mpMRI.…”
Section: Augmented-reality Radical Prostatectomymentioning
confidence: 99%