2017
DOI: 10.1088/1361-6560/aa586c
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional cascaded system analysis of a 50µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis

Abstract: Abstract. High-resolution, low-noise x-ray detectors based on the complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been developed and proposed for digital breast tomosynthesis (DBT). In this study, we evaluated the three-dimensional (3D) imaging performance of a 50 μm pixel pitch CMOS APS x-ray detector named DynAMITe (Dynamic Range Adjustable for Medical Imaging Technology). The two-dimensional (2D) angle-dependent modulation transfer function (MTF), normalized noise po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 61 publications
1
6
0
Order By: Relevance
“…Mainprize et al (2006) measured reductions in MTF of approximately 5% and 15% for angular incidences of 20°and 30°, respectively for a CsI detector at 4 mm −1 . Similar figures were found by Zhao et al (2017) for a CMOS active pixel sensor with a 50 μm pixel pitch (DynAMITe) coupled to a CsI scintillator.…”
Section: Dbt System Presampling Mtf Using Projection Imagessupporting
confidence: 82%
See 2 more Smart Citations
“…Mainprize et al (2006) measured reductions in MTF of approximately 5% and 15% for angular incidences of 20°and 30°, respectively for a CsI detector at 4 mm −1 . Similar figures were found by Zhao et al (2017) for a CMOS active pixel sensor with a 50 μm pixel pitch (DynAMITe) coupled to a CsI scintillator.…”
Section: Dbt System Presampling Mtf Using Projection Imagessupporting
confidence: 82%
“…While the simulations of system MTF and NPS calculated using cascaded systems analysis for the Siemens Mammomat Novation TOMO unit (Zhao and Zhao 2008b) were experimentally validated (Zhao et al 2009) experimental, measured DQE results were not given. Zhao et al (2017) measured the MTF, NPS and DQE as a function of oblique angle incidence for a CMOS active pixel sensor detector (DynAMITe) with 50 μm pixels and combined these data with the cascaded systems theory of (Zhao and Zhao 2008b) to model the impact of angular range, dose and focal spot size for a theoretical step and shoot system. They found that oblique entry of ±30°did not greatly influence inplane DQE but did improve the low frequency sampling in Fourier space and thus improved DQE below 2 mm −1 .…”
Section: System Dqe Calculated In the Reconstructed Planesmentioning
confidence: 99%
See 1 more Smart Citation
“…However, one big obstacle faced for perovskite semiconductors is the serious ion migration effect of perovskite ions, especially under a large electric field to extract the charges induced by X-rays, thus impairing the device signal-to-noise ratio (SNR) and accelerating the degradation of perovskite-based electronic devices. [17,18] Indirect-type X-ray detectors based on scintillation crystals first convert X-rays into UV-vis photons, and followed by photodetector detection through image sensors, such as complementary metal-oxide semiconductor (CMOS), charge-coupled devices (CCDs), thin-film phototransistor (TFT) arrays, and so on, [19,20] which avoids applying large bias and ions migration effect. The development of indirect-type X-ray detection is relatively mature, and now dominating the markets of CT products.…”
Section: Introductionmentioning
confidence: 99%
“…Indirect‐type X‐ray detectors based on scintillation crystals first convert X‐rays into UV–vis photons, and followed by photodetector detection through image sensors, such as complementary metal‐oxide semiconductor (CMOS), charge‐coupled devices (CCDs), thin‐film phototransistor (TFT) arrays, and so on, [ 19 , 20 ] which avoids applying large bias and ions migration effect. The development of indirect‐type X‐ray detection is relatively mature, and now dominating the markets of CT products.…”
Section: Introductionmentioning
confidence: 99%