2011
DOI: 10.1016/j.actbio.2011.05.023
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional bioactive glass implants fabricated by rapid prototyping based on CO2 laser cladding

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(21 citation statements)
references
References 64 publications
0
17
0
Order By: Relevance
“…). The broad vibration bands at around 994–1075 and 500 cm −1 were ascribed to the Si‐O‐Si asymmetric stretching and Si‐O‐Si bending, respectively . On the other hand, P‐O antisymmetric stretching was assigned to a band at 1000–1100 cm −1 , which could have overlapped with that of Si‐O‐Si asymmetric stretching .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…). The broad vibration bands at around 994–1075 and 500 cm −1 were ascribed to the Si‐O‐Si asymmetric stretching and Si‐O‐Si bending, respectively . On the other hand, P‐O antisymmetric stretching was assigned to a band at 1000–1100 cm −1 , which could have overlapped with that of Si‐O‐Si asymmetric stretching .…”
Section: Resultsmentioning
confidence: 99%
“…The broad vibration bands at around 994-1075 and 500 cm À1 were ascribed to the Si-O-Si asymmetric stretching and Si-O-Si bending, respectively. [50][51][52] On the other hand, P-O antisymmetric stretching was assigned to a band at 1000-1100 cm À1 , which could have overlapped with that of Si-O-Si asymmetric stretching. 50,52,53 In BG, phosphorus is in the form of orthophosphate, PO 3À 4 , whose charge is balanced by modifier cation such as Ca 2+ .…”
Section: Resultsmentioning
confidence: 99%
“…This problem causes lower bioactivity of the developed HA coating. Bioactive glass 45S5 and S520 proved higher stability than HA at high temperatures [11] [131]. The simulated body fluid test showed that bioactive glass S520 is more appropriate than 45S5 in laser cladding rapid prototyping [80].…”
Section: Bioglass Bioglass Bioglass Bioglassmentioning
confidence: 92%
“…These materials have very low fracture toughness (usually < 1 MPa.m 1/2 ) compared to cortical bones (2-10 MPa.m 1/2 ) [10]. In the other applications which no load or small loads are induced, the bioactive materials proved excellent treatment results, as an example the middle ear bones replacement [11].…”
Section: A C C E P T E D Accepted Manuscriptmentioning
confidence: 99%
“…In addition to their bioactivity and resorbability, glasses are relatively easy to shape and to produce in microporous structures, making them extremely useful in a variety of scaffold applications [36]. For example, a gel casting approach has recently been demonstrated which allows near net shape three-dimensional fabrication [37].…”
Section: Bioactive Glassesmentioning
confidence: 99%