Three‐dimensional balanced steady state free precession imaging of the prostate: Flip angle dependency of the signal based on a two component T2‐decay model

Abstract: Purpose: To investigate the contrast of three-dimensional balanced steady state free precession (3D bSSFP) in the two component T2 model and to apply the results to optimize 3D bSSFP for prostate imaging at 1.5 Tesla. Materials and Methods:In each of seven healthy volunteers, six 3D bSSFP acquisitions were performed with flip angles (a) equally spaced between 10 and 110 . Predictions of signal and contrast were obtained from synthetic bSSFP images calculated from relaxation parameters obtained from a multi-spi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
8
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 27 publications
1
8
0
Order By: Relevance
“…This is strongly supported by our recent study [24], which showed a significant correlation between LWF and the histological measure of luminal space. The mean and range of gmT 2 , T 2-short , and T 2-long also corresponds well to the previously published values [7,8].…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…This is strongly supported by our recent study [24], which showed a significant correlation between LWF and the histological measure of luminal space. The mean and range of gmT 2 , T 2-short , and T 2-long also corresponds well to the previously published values [7,8].…”
Section: Discussionsupporting
confidence: 90%
“…Although, multi-component T 2 in prostate has been shown before [6,7,8,9,10] only one recent study investigated the application of this technique for cancer diagnosis [10]; however, no direct correlation between MRI and histology has been published. In our study, we validated MR measurements with wholemount histology, and performed statistical analysis to assess the accuracy of this technique in the detection and grading of PCa.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Significant effects particularly on T 2 , measuring rotational diffusion, and T 1ρH measuring H-C dipolar fluctuations (rotational, vibrational or distance fluctuations) were monitored with systems containing silicates undergoing restricted dynamic of tetrapropylammonium interacting with nanoparticles. Mobility of species is directly correlated to such parameters [53][54][55][56][57][58]. Temperature changes induce significant modulation of NMR relaxation, and allow following occlusion of tetrapropylammonium cations into nanoparticles.…”
Section: Introductionmentioning
confidence: 99%
“…This technique has been developed based on the assumption that glandular tissue of prostate is composed of water compartments of different sizes associated with multiple T 2 relaxation times. It has been demonstrated that T 2 decay curves obtained from prostate are mainly biexponential . One may expect that the biexponential T 2 decay of prostate is composed of one term with a longer T 2 attributed to the water protons residing inside the luminal space and another term with a shorter T 2 attributed to the water protons residing within the epithelial and stromal tissue.…”