Threat for human beings due to touch voltages and body currents caused by direct lightning strikes in case of non-isolated lightning protection systems using natural components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 1 publication
1
6
0
Order By: Relevance
“…Previous investigation [17] has shown that the 30/80 μs impulse current satisfies all of the parameters required in the ARP 5412. Additionally, the range of the charge transfer of 30/80 μs impulse current with amplitude between 20 and 200 kA conforms to the statistical charge transfer distribution of the lightning first return stroke current in natural negative ground flashes, which account for more than 90% of the total natural ground flashes [4,6].…”
Section: Introductionmentioning
confidence: 79%
See 3 more Smart Citations
“…Previous investigation [17] has shown that the 30/80 μs impulse current satisfies all of the parameters required in the ARP 5412. Additionally, the range of the charge transfer of 30/80 μs impulse current with amplitude between 20 and 200 kA conforms to the statistical charge transfer distribution of the lightning first return stroke current in natural negative ground flashes, which account for more than 90% of the total natural ground flashes [4,6].…”
Section: Introductionmentioning
confidence: 79%
“…The ablation damage of steel caused by direct lightning current is key to the protection of oil-storage tanks and has been widely investigated. Ablation tests on steel sheets with simulated lightning currents are recognized to be the most valid methods of investigations on the ablation damage of steel [3][4][5][6][7][8][9][10][11][12][13]. The widely adopted four components of the simulated lightning currents applied in ablation tests, which have been stipulated by the society of automobile engineers in the Aerospace Recommended Practice 5412 (ARP 5412) according to the characteristics of natural lightning currents [14,15], are the first return stroke current, the intermediate current, the continuing current and the subsequent stroke current.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Touch voltage is the voltage between an object being touched and a point 1 meter away, assuming that the object being touched is connected to a grounding grid below it (see Figure 1). Touch voltage that is too high must be protected so that it is not dangerous (Kern et al, 2021). Requirements to ensure the safety of humans and livestock and property security from dangers and damage that may arise from the reasonable use of electrical installations (Sni Puil, 2011).…”