2015
DOI: 10.1097/icb.0000000000000072
|View full text |Cite
|
Sign up to set email alerts
|

Third Time Spontaneous Closure of Myopic Macular Hole

Abstract: Dynamic interaction between tensile and degenerative forces, and proliferative and reparative glial elements, may lead to hole remodeling.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…Also reopening of a previously surgically or spontaneously closed MH has been described [5]. A case with multiple spontaneous opening and closure of a myopic MH was reported [6]. Nivolumab-associated uveitis (present in Case 1) has only rarely been reported to cause CME but has never been reported in association with a MH.…”
Section: Discussionmentioning
confidence: 99%
“…Also reopening of a previously surgically or spontaneously closed MH has been described [5]. A case with multiple spontaneous opening and closure of a myopic MH was reported [6]. Nivolumab-associated uveitis (present in Case 1) has only rarely been reported to cause CME but has never been reported in association with a MH.…”
Section: Discussionmentioning
confidence: 99%
“…To date, and to the best of our knowledge, there has only been one previous report of a case of spontaneous closure and reopening of an MH with no history of previous surgery [14]. In that study, the authors reported a case of high myopia with no history of previous surgery in which the spontaneous closure and reopening of the MH occurred three times.…”
Section: Discussionmentioning
confidence: 99%
“…On follow-up at 9 months, it was observed that although the VMT had not released, the macular hole was closed and retinal detachment had regressed slightly. In 2015, Golan and Barak 12 described a highly myopic 75-year-old woman whose macular hole recurred and spontaneously closed 3 times at intervals of several months.…”
Section: Discussionmentioning
confidence: 99%
“…Perifoveal defects in these eyes are also thought to expand due to centrifugal forces around the axis of ocular rotation. 12 Therefore, the incidence of macular holes is higher in eyes with increased axial length. 5 The depth of posterior staphyloma, which is a scleral ectasia that causes axial elongation, also affects the strength of these potential traction forces.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation