2005
DOI: 10.1039/b413282c
|View full text |Cite
|
Sign up to set email alerts
|

Thin chip microsprayer system coupled to quadrupole time-of-flight mass spectrometer for glycoconjugate analysis

Abstract: A thin chip polymer-based microsprayer has been coupled to a hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) and introduced in carbohydrate research. The feasibility of the approach is demonstrated for mapping, sequencing and structural elucidation of glycoconjugates originating from human body fluids and tissues such as a glycopeptide mixture from normal human urine and an isolated and purified GT1 ganglioside fraction from normal adult human brain. The optimization procedure required by each gly… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
53
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 40 publications
(54 citation statements)
references
References 35 publications
1
53
0
Order By: Relevance
“…The ESI plume is clearly visible demonstrating the instant initiation of the electrospray. Under the same ESI-QTOF-MS conditions, the reported [27] in-run reproducibility in terms of sensitivity, spray stability, number of detected components/fragments, ion intensity, and charge state was almost 100%, while the day-to-day reproducibility was 95-100%.…”
Section: Coupling Of the Thin Chip Microsprayer System To High-performentioning
confidence: 75%
See 4 more Smart Citations
“…The ESI plume is clearly visible demonstrating the instant initiation of the electrospray. Under the same ESI-QTOF-MS conditions, the reported [27] in-run reproducibility in terms of sensitivity, spray stability, number of detected components/fragments, ion intensity, and charge state was almost 100%, while the day-to-day reproducibility was 95-100%.…”
Section: Coupling Of the Thin Chip Microsprayer System To High-performentioning
confidence: 75%
“…The voltage on the microelectrode was applied by using a conductive wire with one terminal connected to the chip electrode and the other fixed on the ESI high-voltage plate of the QTOF-MS instrument. Under the formed high electric field, the fluid was electrokinetically driven through the chip microchannel from its inlet-hole toward the outlet-edge where the electrospray process occurred [27]. In the case of QTOF-MS, the ESI source is configured in Z geometry by the orthogonal alignment of the sampling capillary and MS counterelectrode.…”
Section: Coupling Of the Thin Chip Microsprayer System To High-performentioning
confidence: 99%
See 3 more Smart Citations