1993
DOI: 10.1007/bf00125594
|View full text |Cite
|
Sign up to set email alerts
|

Thermoplastic fibre-reinforced composites for dentistry

Abstract: The effect of a deterioration of matrix and matrix-fibre interface, caused by moisture, on the flexural properties (modulus, strength and ultimate strain) of unidirectional E-glass fibre-reinforced thermoplastics [polycarbonate, poly(ethyleneterephthalate glycol) and nylon 1 2] was investigated. Specimens of span/thickness ratio varying from 15 to 30, prepared from pultruded thermoplastic prepregs, were tested in directions parallel to and perpendicular to the fibre orientation as moulded and after immersion i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

1995
1995
2019
2019

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 20 publications
(13 reference statements)
1
4
0
Order By: Relevance
“…The appearance of cracks is the sign of plastic deformation of the wire and later loss of force. This result is in agreement with Jancar et al 30 who affirmed that the possible factors that contraindicate the use of polymer-and fiber-based esthetic wires are in the transverse fractures, fractures due to stress with detachment of the fibers, fractures at the polymer-fiber bond surface, compressive fracture arising from bends located in the fibers, and fractures close to the surface.…”
Section: Discussionsupporting
confidence: 92%
“…The appearance of cracks is the sign of plastic deformation of the wire and later loss of force. This result is in agreement with Jancar et al 30 who affirmed that the possible factors that contraindicate the use of polymer-and fiber-based esthetic wires are in the transverse fractures, fractures due to stress with detachment of the fibers, fractures at the polymer-fiber bond surface, compressive fracture arising from bends located in the fibers, and fractures close to the surface.…”
Section: Discussionsupporting
confidence: 92%
“…In order to vary layer thickness, the deposited layer was treated with SiCl 4 and then additional layers were deposited to give layers of overall desired thickness. Based on the previous results [2,3], PC layers were tested both as deposited and annealed for 10 min at 245 • C. Interphases deposited without using SiCl 4 served as a reference.…”
Section: Methodsmentioning
confidence: 99%
“…Moreover, PCA/bare E-glass fiber composite annealed at 275 °C for 1 h before immersion in water exhibited superior resistance to moisture attack. Resistance against moisture favours the application as an orthodontic wire of this material [248]. Table 6 is a summary of PCA based devices used for dentistry.…”
Section: Polycarbonatesmentioning
confidence: 99%
“…Table 6 is a summary of PCA based devices used for dentistry. [245] Thermoplastic PCA denture base resin [246] PCA based fiber-reinforced composites [247] PCA/bare E-glass fiber composite [248] 7.6.6. Polyurethanes…”
Section: Polycarbonatesmentioning
confidence: 99%