2003
DOI: 10.1063/1.1627172
|View full text |Cite
|
Sign up to set email alerts
|

Thermoelectric Scanning Study of Pt/Pd and Au/Pt Thermocouples up to 960 °C with a Pressure Controlled Sodium Heat-Pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Furthermore, as the thermo-hydraulically linked components such as the evaporator and the compensation chamber were physically separated, the pressure change inside the compensation chamber using a heterogeneous control gas did not affect the intrinsic thermodynamic stability of the pressure-controlled LHP [7,8]. This was the most distinguishable feature of conventional gas pressure-controlled heat pipes, which required tedious procedures to prevent thermodynamic instability due to the presence of the different control gas from the working fluid [11][12][13].…”
Section: Realization Of Tin Freezing Point Using a Loop Heat Pipe-bas...mentioning
confidence: 99%
“…Furthermore, as the thermo-hydraulically linked components such as the evaporator and the compensation chamber were physically separated, the pressure change inside the compensation chamber using a heterogeneous control gas did not affect the intrinsic thermodynamic stability of the pressure-controlled LHP [7,8]. This was the most distinguishable feature of conventional gas pressure-controlled heat pipes, which required tedious procedures to prevent thermodynamic instability due to the presence of the different control gas from the working fluid [11][12][13].…”
Section: Realization Of Tin Freezing Point Using a Loop Heat Pipe-bas...mentioning
confidence: 99%
“…So far, eutectics have been constructed by NMIJ [8,15,18], NPL [19], VNIIOFI [20,21], BNM-LNE [22], BNM-INM [23], BIPM [24], KRISS [25], PTB [26], NIST [27], Chino Corp [28] and Tamagawa University [29]. Figure 2 shows the basic design of a cell.…”
Section: Manufacture Of Fixed-point Cellsmentioning
confidence: 99%
“…The development of eutectics metal-carbon fixed points represents another interesting possibility of overcoming the need of a comparison with the radiation thermometer [4,5]. Co-C (1324 • C), Ni-C (1326 • C) and Pd-C (1504 • C) are some points that could be used to extend the fixed-point calibration above the copper point.…”
Section: Discussionmentioning
confidence: 99%