2002
DOI: 10.1016/s1359-4311(02)00004-2
|View full text |Cite
|
Sign up to set email alerts
|

Thermo-economical analysis between new absorption–ejector hybrid refrigeration system and small double-effect absorption system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 37 publications
(10 citation statements)
references
References 6 publications
0
8
0
Order By: Relevance
“…Concerning the nozzle shape and position an evident link between primary nozzle position and ejector performance (COP, CC and critical condenser pressure) in the case of a refrigerator with jet was found [101]. The importance of Nozzle Exit Position (NXP) and shape was also investigated by means of CFD and experimental techniques finding the great influence of the nozzle position as ejector design parameter [60,62,[208][209][210].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Concerning the nozzle shape and position an evident link between primary nozzle position and ejector performance (COP, CC and critical condenser pressure) in the case of a refrigerator with jet was found [101]. The importance of Nozzle Exit Position (NXP) and shape was also investigated by means of CFD and experimental techniques finding the great influence of the nozzle position as ejector design parameter [60,62,[208][209][210].…”
Section: Discussionmentioning
confidence: 99%
“…However, it likely will remain restricted to industrial applications, as it is unsuitable for domestic use due to its toxicity [13]. Another interesting option is methanol thanks to its appropriate thermo-physical properties, low environmental impact and low cost, and it is able to provide a cooling effect at evaporation temperatures below the freezing point of water [109,[206][207][208][209]. On the other hand, methanol is toxic and highly flammable; therefore, important preventive measures should be taken.…”
Section: Working Fluids In Ejector Refrigerationmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering the current British economic situation, i 5 5.0% (base interest rate of Bank of England), Cele 5 £0.10 kWh À1 (EDF Energy, East Midland standard price), running hours is 1000 h per year [10], and life-year in operation is n 5 20 as both PV panel and TEC unit are solid-state equipments except fans and a blower. One of the advantages is longer life and no or little maintenance, compared to the traditional cooling systems.…”
Section: Economic Analysismentioning
confidence: 99%
“…As is well known, ejectors can increase the pressure and do not consume mechanical energy directly, which are the main characteristics of ejectors [17][18][19][20]. Due to these characteristics, applying an ejector may be a simpler and safer technologically than applying mechanical devices, which can increase pressure, such as a compressor, pump.…”
Section: Introductionmentioning
confidence: 99%