2006
DOI: 10.1007/bf02704144
|View full text |Cite
|
Sign up to set email alerts
|

Thermally stimulated discharge conductivity in polymer composite thin films

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 1 publication
1
7
0
Order By: Relevance
“…The pellet was then annealed at 500 °C for 1 h before current measurements. The thickness of the sample was measured by the compound microscope in conjunction with an occulometer having least count of 15⋅38 μm, similar to method reported by Sangawar et al (2006). The thickness of the sample was kept constant throughout the work and was of the order of 0⋅1692 cm.…”
Section: Methodsmentioning
confidence: 99%
“…The pellet was then annealed at 500 °C for 1 h before current measurements. The thickness of the sample was measured by the compound microscope in conjunction with an occulometer having least count of 15⋅38 μm, similar to method reported by Sangawar et al (2006). The thickness of the sample was kept constant throughout the work and was of the order of 0⋅1692 cm.…”
Section: Methodsmentioning
confidence: 99%
“…At room temperature the solution was allowed to evaporate completely, to obtain smooth, pin hole free thin films. In this way, polyblend specimens of 4 × 4 cm were prepared by solution evaporation technique used by Sangawar et al [12,13], Belsare et al [14], Meghal Priya et al [15]. To remove the traces of solvent, the above prepared specimens were subjected to heat at constant temperature, the resultant samples were used for structural, electrical studies and for irradiation.…”
Section: Sample Preparationmentioning
confidence: 99%
“…The thickness of the polyblends samples were measured by compound microscope in conjunction with an occulometer having least count 15.38 μm used by Belsare et al [14], Sangawar et al [13]. The thickness of all samples was kept constant and it is of the order of 46.14 μm.…”
Section: Thickness Measurementmentioning
confidence: 99%
“…Then, the solvent is allowed to evaporate slowly inside an oven at the constant rate of 1 o C/min for 24 h. After that, the dried sample is subjected to room temperature outgassing in an air at 60 o C at the pressure of 10 -5 torr for a further period of 24 h to remove residual solvent. The polymer film is, then, gently pealed-off from the glass plate [16]. The sample is a circular disc-shaped foil having diameter of 5 cm.…”
Section: Synthesis Of Pure Polysulfone (Psf) Filmsmentioning
confidence: 99%