Thermal conductivity coefficient of cement-based mortars as air relative humidity function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(12 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…Modern building materials should meet minimum mechanical property and durability requirements so as to be successfully used in construction fields. Furthermore, it has been suggested that energy savings can be made through the proper insulation of a structure; therefore, thermal conductivity is becoming an important factor in determining the properties of modern building materials [ 30 ]. This study is aimed to evaluate the effect of crushed and expanded WG in production of lightweight concretes and their effect on thermal and mechanical properties.…”
Section: Introductionmentioning
confidence: 99%
“…Modern building materials should meet minimum mechanical property and durability requirements so as to be successfully used in construction fields. Furthermore, it has been suggested that energy savings can be made through the proper insulation of a structure; therefore, thermal conductivity is becoming an important factor in determining the properties of modern building materials [ 30 ]. This study is aimed to evaluate the effect of crushed and expanded WG in production of lightweight concretes and their effect on thermal and mechanical properties.…”
Section: Introductionmentioning
confidence: 99%
“…The thermal conductivity λ [W/(m.°C)] and heat capacity C v [J/(kg.°C)] of the concrete samples were determined using heat transfer analyzer model ISOMET 2104 (Slovakia) [17][18][19]. The tests were conducted at a temperature of 20 ± 5°C and a relative humidity of 90-95 % using concrete samples of 25 × 25 × 6 cm in size.…”
Section: Test Methodsmentioning
confidence: 99%
“…The thermal conductivity coefficient was determined for the dry state. Exposing the mortar to humidity can result in a deterioration of the parameter [Siwińska and Garbalińska, 2011]. The incinerated sewage sludge decreases the overall bulk density of mortars, due to the high porosity of aggregates.…”
Section: Properties Of Cement Mortars With Waste Aggregatementioning
confidence: 99%