2021
DOI: 10.3390/en14092545
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Behavior of a BIPV Combined with Water Storage: An Experimental Analysis

Abstract: Buildings play an active role in the global energy consumption and are required to not only minimize their energy use, but also generate energy in a sustainable manner. The integration of renewable energies in building elements can improve their overall performance, as they are able to replace common construction materials, while offering both electrical and thermal energy. The scope of this paper is to present the first results of an experimental study of a Building-Integrated Photovoltaic system combined wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 16 publications
(13 reference statements)
0
5
0
Order By: Relevance
“…The ARGUS Presence Master with IR detected illuminance within a range of 10 to 1000 lux [23]. Additionally, meteorological data were collected on-site through a weather station installed on the roof of Solar XXI [25]. The installed sensors allowed monitoring diverse aspects of the monitored room, such as temperature; relative humidity; carbon dioxide (CO 2 ) concentration, with a SED-CO 2 -G-5045 [22]; and luminosity, with an ARGUS Presence Master with IR [23], which guided the implemented algorithms in the installed systems.…”
Section: Monitoring Laboratorymentioning
confidence: 99%
See 3 more Smart Citations
“…The ARGUS Presence Master with IR detected illuminance within a range of 10 to 1000 lux [23]. Additionally, meteorological data were collected on-site through a weather station installed on the roof of Solar XXI [25]. The installed sensors allowed monitoring diverse aspects of the monitored room, such as temperature; relative humidity; carbon dioxide (CO 2 ) concentration, with a SED-CO 2 -G-5045 [22]; and luminosity, with an ARGUS Presence Master with IR [23], which guided the implemented algorithms in the installed systems.…”
Section: Monitoring Laboratorymentioning
confidence: 99%
“…The ARGUS Presence Master with IR detected illuminance within a range of 10 to 1000 lux [23]. Additionally, meteorological data were collected on-site through a weather station installed on the roof of Solar XXI [25].…”
Section: Monitoring Laboratorymentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the aggravation of an energy crisis, Scientists recommend exploiting renewable sources of energy [1][2][3] and to simultaneously manage the energy consumption as a last step to reduce the severity of this problem [4][5][6][7]. The energy management field is under continuous development nowadays due to the diversity and complexity of components involved in modern thermal systems.…”
Section: Introductionmentioning
confidence: 99%