Thermal and spectroscopic analysis of florfenicol irradiated in the solid-state

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…The first one started at around 170 °C while the second step occured at around 220 °C and continued until all sample was completely degraded after 600 °C [46] . Similaly, two stages of mass loss were observed at around 150 °C and 250 °C in TGA curve of Florfenicol [47] . TGA profile of DOX‐FLO@AgNPs showed a gradual mass loss between 100 °C and 500 °C and a rapid weight reduction at around 600 °C could be due to both the dehydration and the decomposition of organics compounds.…”
Section: Resultsmentioning
confidence: 93%
See 2 more Smart Citations
“…The first one started at around 170 °C while the second step occured at around 220 °C and continued until all sample was completely degraded after 600 °C [46] . Similaly, two stages of mass loss were observed at around 150 °C and 250 °C in TGA curve of Florfenicol [47] . TGA profile of DOX‐FLO@AgNPs showed a gradual mass loss between 100 °C and 500 °C and a rapid weight reduction at around 600 °C could be due to both the dehydration and the decomposition of organics compounds.…”
Section: Resultsmentioning
confidence: 93%
“…[46] Similaly, two stages of mass loss were observed at around 150 °C and 250 °C in TGA curve of Florfenicol. [47] TGA profile of DOX-FLO@AgNPs showed a gradual mass loss between 100 °C and 500 °C and a rapid weight reduction at around 600 °C could be due to both the dehydration and the decomposition of organics compounds. The higher decomposed temperature of the DOX-FLO@AgNPs, compared to the raw materials, could be explained by the interaction of DOX/ FLO with the Alginate/Chitosan nanocarrier making the synthesized particles more thermal stable.…”
Section: Chemistryselectmentioning
confidence: 99%
See 1 more Smart Citation
“…The methodology of measurements by the, FT-IR, EPR, was the same as described for florfenicol investigation 19 .…”
Section: Ph Measurementsmentioning
confidence: 99%
“…Differential Scanning Calorimetry (DSC) results for selected formulations are shown in Supplementary material (Figure SM3) . FF fusion peak can be observed at 152 C. 42,46 The glass transition temperature of PLGA is 37e38 C. 47 The formulation P50 presents a fusion peak at 155 C and can be associated with crystalline FF. The difference with pure FF is possibly related to interactions with the polymeric matrix.…”
Section: Resultsmentioning
confidence: 99%