Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
67
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 42 publications
(67 citation statements)
references
References 32 publications
0
67
0
Order By: Relevance
“…However, PBS can result in larger lateral dose fall‐off due to the width of the incoming beam . This may be reduced with the use of smaller spot sizes and patient‐specific apertures or collimation at the nozzle . Dosimetric studies have demonstrated improved sparing of OARs using PBS‐PT as compared to DS‐PT using these modifications …”
Section: Discussionmentioning
confidence: 99%
“…However, PBS can result in larger lateral dose fall‐off due to the width of the incoming beam . This may be reduced with the use of smaller spot sizes and patient‐specific apertures or collimation at the nozzle . Dosimetric studies have demonstrated improved sparing of OARs using PBS‐PT as compared to DS‐PT using these modifications …”
Section: Discussionmentioning
confidence: 99%
“…Plan‐specific film response correction factors were determined for a set of three brain treatments previously studied in the works of Smith and Moignier . A single radiological depth near the center of the PTV was chosen as the candidate depth in which a representative lateral dose profile of the treatment plan could be benchmarked.…”
Section: Methodsmentioning
confidence: 99%
“…Plan-specific film response correction factors were determined for a set of three brain treatments previously studied in the works of Smith 29 and Moignier. [30][31][32] A single radiological depth near the center of the PTV was chosen as the candidate depth in which a representative lateral dose profile of the treatment plan could be benchmarked. About this depth, a series of SOBP profiles, which were characteristic of the energy ranges experienced by the film dosimeter at the plane of measurement, were created and optimized using the Raystation treatment planning system (Raysearch Labs, Sweden) and exported as a PLD file.…”
Section: B2 Spread-out Bragg Peak Irradiationsmentioning
confidence: 99%
“…The potential clinical delivery improvement by spot trimming was reported in a retrospective study of five intracranial cases . A representative result is presented in Fig.…”
Section: New Horizons: Beam Delivery Systemsmentioning
confidence: 82%
“…Comparison of dose distribution between Untrimmed and Trimmed plans using an in‐house treatment planning system capable of including the beam trimmer ( RDX ) …”
Section: New Horizons: Beam Delivery Systemsmentioning
confidence: 99%