2010
DOI: 10.1016/j.applthermaleng.2010.07.003
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical and experimental studies on optimum heat rejection pressure for a CO2 heat pump system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(16 citation statements)
references
References 16 publications
1
15
0
Order By: Relevance
“…Similar work was done by Zhang, Fan, Wang and Shen [19] and a different correction to Liao, Zhao and Jakobsen [9] was proposed.…”
Section: Subscriptsmentioning
confidence: 61%
See 2 more Smart Citations
“…Similar work was done by Zhang, Fan, Wang and Shen [19] and a different correction to Liao, Zhao and Jakobsen [9] was proposed.…”
Section: Subscriptsmentioning
confidence: 61%
“…Kauf [8] Single-stage valve-expansion (1) SD 5.8% for p opt Liao, Zhao and Jakobsen [9] Single-stage valve-expansion (2) SD 1% for p opt Sarkar, Bhattacharyya and Gopal [10] Single-stage valve-expansion (3) N/A Sarkar, Bhattacharyya and Gopal [23] Single-stage valve-expansion (4) R 2 ¼ 0.995 for p opt Chen and Gu [11] Single-stage valve-expansion (5) (6) SD ¼ 0.94% for p opt Kim, Won and Kim [17] Single-stage valve-expansion (7) N/A Aprea and Maiorino [18] Single-stage valve-expansion (8) More accurate than Liao, Zhao and Jakobsen [9] for specific experimental p opt ; Zhang, Fan, Wang and Shen [19] Single-stage valve-expansion (9) More accurate than Liao, Zhao and Jakobsen [9] for specific experimental p opt ; Qi, He, Wang and Meng [16] Single-stage valve-expansion (10) MaxD 5% for experimental p opt ; MaxD 6% for real system COP Wang, Tuo, Cao and Xing [20] Single-stage valve-expansion (11) (12) MaxD ¼ 5.5% for experimental p opt , corresponding COP loss 1.3% Agrawal, Bhattacharyya and Sarkar [12] Two-stage valve-expansion (13) [13] Single/two-stage valve-expansion (16) N/A Ge and Tassou [15] Supermarket boost system (17) N/A Ge and Tassou [14] Supermarket boost system (18) AD ¼ 0.45%, MaxD ¼ 1.89% for p opt Sarkar [22] Single-stage ejector-expansion (19) R 2 ¼ 0.999 for p opt Elbel and Hrnjak [27] Single-stage ejector-expansion (20) N/A Xu, Chen, Tang and Zhu [24] Single-stage ejector-expansion (21) N/A Yari [21] Two-stage ejector-expansion (22) R 2 ¼ 0.9998 for p opt Fig. 2.…”
Section: Literature Cycle Description Equations Statisticsmentioning
confidence: 96%
See 1 more Smart Citation
“…Based on the previous researches on pure R744 heat pump by our research group, R744/R290 mixture is proposed as a potential alternative refrigerant used in heat pump systems for water heating and space heating [7]. Then it is essential to confirm which composition of mixture is optimum, or at least appropriate, for the certain heat pump application.…”
Section: Introduction mentioning
confidence: 99%
“…The unique The optimal discharge pressure is one of the research hotspots in the trans-critical CO2 systems. In recent years, many theoretical analysis and experimental investigations were carried out on this topic [2][3][4][5][6][7][8][9][10][11], and some stressed on the optimal discharge pressure control [12][13][14]. However, most of these studies focused on the operating conditions when the CO2 temperature at the gas-cooler outlet is above the critical temperature.…”
Section: Introductionmentioning
confidence: 99%