1991
DOI: 10.1007/bf00422879
|View full text |Cite
|
Sign up to set email alerts
|

The validation and application of the technicon H*1 for the complete automated evaluation of laboratory animal haematology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0

Year Published

1993
1993
2013
2013

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 1 publication
0
13
0
Order By: Relevance
“…As LUC can be reactive lymphocytes, blasts, or monocytes, the absolute LUC count was added to automated lymphocyte (lymphocyte + LUC) or monocyte (monocyte + LUC) counts and these combined counts were compared with manual monocyte and lymphocyte counts. Inclusion of LUC in the monocyte count improved the association of the automated monocyte count with the manual count, and median monocyte counts were no longer significantly different between methods.…”
Section: Resultsmentioning
confidence: 99%
“…As LUC can be reactive lymphocytes, blasts, or monocytes, the absolute LUC count was added to automated lymphocyte (lymphocyte + LUC) or monocyte (monocyte + LUC) counts and these combined counts were compared with manual monocyte and lymphocyte counts. Inclusion of LUC in the monocyte count improved the association of the automated monocyte count with the manual count, and median monocyte counts were no longer significantly different between methods.…”
Section: Resultsmentioning
confidence: 99%
“…Comparison between HCT values obtained by the Technicon H*1 and those obtained using the microhematocrit method is shown in Figure 1. The correlation (r 2 ) in the iron‐treated group was .91 (n = 110) and .84 (n = 100) in the placebo group for samples collected at 1,2, 3, and 4 weeks after treatment (lambs 10–33 days of age) (data not shown).…”
Section: Resultsmentioning
confidence: 99%
“…The Technicon H*1 automated hematology analyzer is a versatile and flexible diagnostic tool for many species 2–4 . It was useful for analyzing ovine blood and made it possible to diagnose anemia in young lambs by differentiating between the new and old populations of RBCs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Any bias between the two methods was evaluated for each sample and the result reported as the percentage difference with respect to the manual method. The data were also used to calculate Sensitivity Ratio (SR) (Davies and Fisher, 1991). This ratio takes account of the slope of the linear regression and the analytical error or variability associated with each method.…”
Section: Discussionmentioning
confidence: 99%