The Use of Electrocochleography in the Diagnosis, Assessment, and Monitoring of Endolymphatic Hydrops

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0
2

Year Published

1985
1985
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(9 citation statements)
references
References 12 publications
1
6
0
2
Order By: Relevance
“…There was a flat or high tone hearing loss in 84 per cent of all patients and all those with severe loss (Type 3) had this audiometric configuration. These findings are consistent with studies reported by Ferraro et al (1983) and Campbell et al (1992b).…”
Section: Discussionsupporting
confidence: 94%
“…There was a flat or high tone hearing loss in 84 per cent of all patients and all those with severe loss (Type 3) had this audiometric configuration. These findings are consistent with studies reported by Ferraro et al (1983) and Campbell et al (1992b).…”
Section: Discussionsupporting
confidence: 94%
“…ECochG has been historically a test used for the assessment of endolymphatic hydrops, associated with Ménière's disease. [ 8 9 10 17 ] Only recently has ECochG been studied in cases of SCDS. The SP/AP ratio is commonly elevated, and often decreases after surgical plugging of the superior semicircular canal.…”
Section: Discussionmentioning
confidence: 99%
“…Electrocochleography (ECochG) is an electrophysiologic test used for the diagnosis of endolymphatic hydrops, especially as seen in Ménière's disease. [ 8 9 15 17 ] Patients with SCDS have recently also been found to have an elevated summating potential to action potential (SP/AP) ratio, as measured by ECochG,[ 2 ] and this abnormal ratio appears to often correct after surgery for plugging the dehiscent semicircular canal. [ 1 14 22 ] Intraoperative monitoring procedures such as ECochG or auditory brainstem responses (ABR) are commonly used during vestibular schwannoma surgery.…”
Section: Introductionmentioning
confidence: 99%
“…The band-pass filter was set to 3–3,000 Hz; a high pass filter of 3 Hz was used because the SP, as a direct current potential, is particularly sensitive to high pass filter settings. The use of a high pass filter of 3 Hz, is thought to minimize the distortion present in the SP signal (Ferraro et al, 1983 ).…”
Section: Methodsmentioning
confidence: 99%