2015
DOI: 10.1016/j.electacta.2015.04.072
|View full text |Cite
|
Sign up to set email alerts
|

The use of different glucose oxidases for the development of an amperometric reagentless glucose biosensor based on gold nanoparticles covered by polypyrrole

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
53
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 64 publications
(57 citation statements)
references
References 44 publications
4
53
0
Order By: Relevance
“…It was found that recoveries of Ppy (21h) /GOx/AuNPs/GR electrodes were in the range of 97–99 %, which is similar to results obtained with electrode modified with AuNP, 1,10‐phenanthroline‐5,6‐dione and Ppy(22h) layer (98 %) or higher in comparison to electrode based on GOx immobilised on an overoxidized Ppy film decorated with electrochemically deposited AuNP (96 %) . Therefore, the developed electrochemical biosensor based on Ppy (21h) /GOx/AuNPs/GR electrode followed by amperometric glucose detection is applicable for the determination of glucose in human serum samples.…”
Section: Resultssupporting
confidence: 74%
“…It was found that recoveries of Ppy (21h) /GOx/AuNPs/GR electrodes were in the range of 97–99 %, which is similar to results obtained with electrode modified with AuNP, 1,10‐phenanthroline‐5,6‐dione and Ppy(22h) layer (98 %) or higher in comparison to electrode based on GOx immobilised on an overoxidized Ppy film decorated with electrochemically deposited AuNP (96 %) . Therefore, the developed electrochemical biosensor based on Ppy (21h) /GOx/AuNPs/GR electrode followed by amperometric glucose detection is applicable for the determination of glucose in human serum samples.…”
Section: Resultssupporting
confidence: 74%
“…A tangible application of amperometric immunosensor is for the measurement of β‐HCG level in advanced pregnancy testing . In another work, German et al established a glucose‐based amperometric sensor by utilizing gold nanoparticle along with electron transfer mediator and different immobilized glucose oxidase that were sourced from Penicillium funiculosum, Penicillium adametzii , or Aspergillus niger that were cross‐linked with glutaraldehyde . They observed a linear concentration range and the glucose oxidase from Penicillium funiculosum exhibited a limit of detection of 0.024 mmol L −1 .…”
Section: Biosensorsmentioning
confidence: 99%
“…Nanoparticles were used to enhance glucose oxidase electrode in the literature. 35,[43][44][45][46] German The effects of enzyme immobilization conditions such as Chi, GOD and GAL concentrations were also investigated and current responses were given for 3 mM glucose solution in the Fig. 5 A, B and C, respectively.…”
Section: The Effect Of Znonp Modification On Current Responsementioning
confidence: 99%
“…ZnO nanomaterials have been widely used for this purpose. [40][41][42][43] The present study deals with the fabrication of a glucose biosensor based on redox polymers such as PPy and POA. Construction of biosensor was optimized in terms of PPy and POA synthesis parameters, enzyme immobilization conditions and also the amount of ZnONP by comparing current response in the glucose solution.…”
Section: Introductionmentioning
confidence: 99%