1984
DOI: 10.1088/0031-9155/29/9/008
|View full text |Cite
|
Sign up to set email alerts
|

The use of cadmium telluride detectors for the qualitative analysis of diagnostic x-ray spectra

Abstract: A method is introduced for the evaluation of x-ray spectra from x-ray machines operating in the range 50-100 kVp using a cadmium telluride (CdTe) detector with low detection efficiency. The pulse height distribution obtained with this kind of detector does not represent the true photon spectra owing to the presence of K-escape, Compton scattering, etc.; these effects were evaluated using a Monte Carlo method. A stripping procedure is described for implementation on a Univac 1100/82 computer. The validity of ou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0
5

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(33 citation statements)
references
References 15 publications
0
28
0
5
Order By: Relevance
“…This was useful to determine the best value for the parameter a and b in Eqs. (13). In theory a and b should be equal to the size of the anode pad.…”
Section: Testing the Flux Independent Algorithmsmentioning
confidence: 99%
See 1 more Smart Citation
“…This was useful to determine the best value for the parameter a and b in Eqs. (13). In theory a and b should be equal to the size of the anode pad.…”
Section: Testing the Flux Independent Algorithmsmentioning
confidence: 99%
“…Further, we develop a model to account for a flux dependent incomplete charge collection. The algorithm corrects each pixel's spectrum individually and is based on the method of stripping, 13 correcting for each distorting effects independently. Our aim is that we with this algorithm are able to correct the measured spectra for distorting effects effectively, fast, and reliable, making the method applicable in applications like luggage screening.…”
Section: Introductionmentioning
confidence: 99%
“…The measured spectra were corrected by the response function of the detector using the stripping procedure (Di Castro et al, 1984) implemented using a Matlab program. This procedure takes into account the K-escape, Compton scattering and detector efficiency corrections.…”
Section: X-ray Spectra Measurementsmentioning
confidence: 99%
“…O método de referência para medição da CSR na faixa de energias de diagnóstico por imagem utiliza uma câmara de ionização calibrada e filtros de Al ou Cu de alto grau de pureza 13 . Alternativamente, é possível estimar a CSR de feixes de raios X a partir dos espectros medidos, após sua adequada correção e conversão para unidades de kerma no ar 14 .…”
Section: Introductionunclassified