2020
DOI: 10.1016/j.ajog.2019.07.023
|View full text |Cite
|
Sign up to set email alerts
|

The use of a hybrid mannequin for the modern high-fidelity simulation in the labor ward: the Italian experience of the Ecografia Gestione Emergenze Ostetriche (EGEO) group

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 35 publications
0
6
0
Order By: Relevance
“…Although most medical simulation training uses manikins, the use of live mock patients was especially helpful for testing our protocol because of the difficulty of maneuvering a real patient, as opposed to a stiff manikin, through the turning steps. 28 This was especially true when determining how far to pull the patient laterally in order to complete the maneuver with the fewest readjustments.…”
Section: Discussionmentioning
confidence: 99%
“…Although most medical simulation training uses manikins, the use of live mock patients was especially helpful for testing our protocol because of the difficulty of maneuvering a real patient, as opposed to a stiff manikin, through the turning steps. 28 This was especially true when determining how far to pull the patient laterally in order to complete the maneuver with the fewest readjustments.…”
Section: Discussionmentioning
confidence: 99%
“…Not surprisingly, our data showed that the accuracy and the precision in measuring both the AoP and the HPD was increased following the practical part of the course while the quality of the ultrasound images obtained at transperineal scanning was not better among the midwives who were exposed to the practical training on the simulator. This may be due to the fact that the IUSim-TM simulator used for this study is composed by a PC sys-tem displaying previously acquired transperineal ultrasound video clips from a library of different clinical cases from which the fetal head station can be measured [20]. Therefore, while extremely useful for the visual interpretation of the ultrasound findings and for the practical calculation of the AoP and the HPD, this type of simulator does not teach how to acquire the sonographic images on the correct plane.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, our study is the first which has been conducted with the use of a dedicated simulator for transperineal ultrasound. The potential usefulness of this ultrasound-friendly mannequin in the simulated management of intrapartum complications has been recently highlighted [20]. The use of a simulator obviates the need of patient participation and avoids bedside live training which may either create discomfort to the woman in active labor or embarrass the practitioner with a low confidence in transperineal ultrasound examination [24,25].…”
Section: Simulation In Obstetrics 125mentioning
confidence: 99%
See 1 more Smart Citation
“…The structure of emergency capability of unconventional emergencies in colleges and universities refers to the composition and proportion of each element of the emergency capability of unconventional emergencies in colleges and universities [ 4 ]. The elements of emergency response capability of unconventional emergencies in colleges and universities and their proportional interaction effect determine the state of emergency response capability of unconventional emergencies in colleges and universities [ 5 ]. The influencing factors of emergency response ability of unconventional emergencies in colleges and universities mainly focus on personnel quality, resource support, cooperative response, management ability, and so on.…”
Section: Introductionmentioning
confidence: 99%