The two normal-incidence monochromator beam lines of PTB at BESSY II

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(15 citation statements)
references
References 7 publications
0
15
0
Order By: Relevance
“…PTB provides the calibration of radiation detectors and sources as well as the characterization of optical components in the UV and VUV range (Richter et al, 2001;Richter & Ulm, 1999). Fig.…”
Section: The Methods and Procedures Of Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…PTB provides the calibration of radiation detectors and sources as well as the characterization of optical components in the UV and VUV range (Richter et al, 2001;Richter & Ulm, 1999). Fig.…”
Section: The Methods and Procedures Of Calibrationmentioning
confidence: 99%
“…A spherical grating maps the entrance slit in the first spectral order into the exit slit, where the radiation of the selected wavelength is detected by a photomultiplier tube. The corresponding wavelength and the spectral resolution depend on the angular position of Figure 5: The normal -incidence monochromator beam line used for calibration of radiation sources (Richter et al, 2001).…”
Section: The Methods and Procedures Of Calibrationmentioning
confidence: 99%
“…11 Another major improvement as compared to the BESSY II station is the fact that the distance from the MLS primary source to the transfer device and the distance from the source under test to the transfer device stays the same, ensuring that the same area of the optical components of the transfer device is illuminated in each case. The transfer station consists of a focusing ellipsoidal grazing incidence mirror under a 10 • incidence angle and a dedicated grating monochromator with a NI and a GI configuration for the respective wavelength regions.…”
Section: Principle Of Setupmentioning
confidence: 99%
“…[8][9][10] A variety of different sources have been calibrated this way, such as deuterium lamps, 11 laser-driven light sources, hollow cathode sources, 12 Penning discharge sources, 13 electron-beam excitation sources, 14 electron cyclotron resonance sources, 15 or gas-jet sources. 16 Special hollow cathode-based sources were developed and calibrated by PTB and subsequently used as transfer standards for the calibration of the VUV telescopes at the SOHO (Solar and Heliospheric Observatory) solar mission 17,18 or for other missions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation