Abstract:With the advancement in technology and lower operating voltage, new standards have evolved in circuit layout and design. Some of these new standards have increased the difficulties of the physical failure analysis process, especially on the front-end. The phenomenon described in this paper is the unusual voltage contrast (VC) and conductive atomic force microscope (C-AFM) curve on a non-isolated active region. The model and mechanism are demonstrated for front-end failure analysis. Based on this, the solution … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.