“…In previous work involving an animal model with osteoporosis, the biomechanical characteristics of trabecular implants was examined. 42 It was found that high strength characteristics are inherent to trabecular tantalum. Trabecular tantalum implants were investigated in a histological examination as well.…”
Our study showed that the evaluated implants have good BIC features. Furthermore, based on histomorthometry and histology, Porous tantalum Trabecular Metal (A) and Trabecular Titanium (B) implants exhibit higher BIC with bone tissue.
“…In previous work involving an animal model with osteoporosis, the biomechanical characteristics of trabecular implants was examined. 42 It was found that high strength characteristics are inherent to trabecular tantalum. Trabecular tantalum implants were investigated in a histological examination as well.…”
Our study showed that the evaluated implants have good BIC features. Furthermore, based on histomorthometry and histology, Porous tantalum Trabecular Metal (A) and Trabecular Titanium (B) implants exhibit higher BIC with bone tissue.
“…Зокрема, у жінок із постменопаузальним остеопорозом і пацієнтів із ревматоїдним артритом підтверджено високий рівень у крові TGF-β [49], прозапального цитокіна, який активує диференціацію остеокластів із попередників через RANKL та призводить до підвищення процесу резорбції кістки [50]. В експериментальних дослідженнях порівняно різні види пористих металевих матеріалів, які використовують для виготовлення ацетабулярних компонентів за умов нормальної кісткової тканини [51][52][53] та в разі моделювання остеопорозу шляхом оваріоектомії [54][55][56]. Доведено високі остеоінтегративні якості різновидів пористих титану і танталу.…”
Section: перебудова кісткової тканини навколо ендопротеза кульшового суглоба після хірургічного втручанняunclassified
“…Доведено високі остеоінтегративні якості різновидів пористих титану і танталу. Проте формування кістки та показник остеоінтеграції цих матеріалів були нижчими в разі моделювання остеопорозу, ніж у тварин із нормальною будовою кістки [54,55], а найбільші руйнівні навантаження витримувала кісткова тканина з імплантатами з пористого танталу [56]. Також опубліковані роботи щодо використання титанових матеріалів для дентальної імплантології в експериментах на моделі з дефіцитом естрогенів (модель остеопорозу/ остеопенії) та показано, що за цих умов пригнічується формування губчастої кісткової тканини навколо імплантата в терміни 4-24 тижні після встановлення [57][58][59][60].…”
Section: перебудова кісткової тканини навколо ендопротеза кульшового суглоба після хірургічного втручанняunclassified
Objective. Basing on the analysis of the scientific literature to study the prevalence of osteoporosis and osteopenia among patients with hip osteoarthritis undergoing THA and to establish the influence of osteoporosis/osteopenia on the choice of implants and on the restoration of the joint function after the surgery. Osteoporosis and osteopenia are manifested in 21-32 % patients undergoing hip arthroplasty. Low bone mass may be a cause of intraoperative (periprosthetic hip fractures) and postoperative complications. In patients with low bone mass bone remodeling with an increased resorption and inhibition of bone formation around hip components can lead to increasing of its micro-movements, the formation of fibrous tissues, and diminution of implants survivorship. In patients with normal bone mineral density (BMD) also the loss of bone tissue around the acetabular cup can occur; it can occur up to 20-60 % in the first three years post operation, which can lead to the cup instability. But the dynamics of changes in bone tissue around the acetabular component in patients with osteoporosis/osteopenia is nowadays poorly understood. We suppose that porous acetabular components have advantages in patients with low BMD. Due to the elastic modulus which is closely similar to cancellous bone, as well as the corresponding porosity, which facilitates osteointegration and gives a reliable secondary biological fixation of the acetabulum. Rehabilitation and restoration of kinematic and support function of the hip joint after arthroplasty is an important issue for patients with low BMD. Gait disturbance can persist 12 months after surgery. One of the reasons is the weakness of the muscles of the femur. Rehabilitation after total hip arthroplasty leads to faster recovery, but particularities of rehabilitation in patients with low bone mass are not fully studied.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.