2012
DOI: 10.1016/j.clinimag.2011.09.009
|View full text |Cite
|
Sign up to set email alerts
|

The role of proton MR spectroscopy and apparent diffusion coefficient values in the diagnosis of malignant thyroid nodules: preliminary results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
13
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 28 publications
1
13
0
Order By: Relevance
“…Diffusion measurement is eventually sum of vectoral quantities, 3 orthogonal diffusion vector gradients; G X , G y , G z are used for calculation of ADC, sum of the square root of these vector magnitudes is the real ADC value and mostly favorable in isotropic diffusion Yoshikawa et al, 2006). Free or isotropic diffusion occurs when movement of water molecules is completely random and restricted, anisotropic diffusion occurs when the motion of water is restricted due to the barriers within cell membranes and macromolecules, signal measured from MRI can be sensitized to water diffusion by addition of balanced diffusion-sensitive, magnetic field gradients and this diffusionsensitizing gradients which acquire MR signals, are the real good contrast DW images because of the diffusion of water protons Aydin et al, 2012a;Koh et al, 2007;Le Bihan et al, 1988). The MR signal obtained by diffusion-sensitizing gradients are equated by: S (b) = So -(bxADC) , S (b) is the measured diffusion signal, So is the signal intensity without diffusion, b is the b-value (sec/mm 2 ) for determining the magnitude, duration and time between the pair of gradients and ADC of water molecules Aydin et al, 2012a;Koh et al, 2007).…”
Section: General Knowledge About Current Dwi Techniquementioning
confidence: 99%
See 4 more Smart Citations
“…Diffusion measurement is eventually sum of vectoral quantities, 3 orthogonal diffusion vector gradients; G X , G y , G z are used for calculation of ADC, sum of the square root of these vector magnitudes is the real ADC value and mostly favorable in isotropic diffusion Yoshikawa et al, 2006). Free or isotropic diffusion occurs when movement of water molecules is completely random and restricted, anisotropic diffusion occurs when the motion of water is restricted due to the barriers within cell membranes and macromolecules, signal measured from MRI can be sensitized to water diffusion by addition of balanced diffusion-sensitive, magnetic field gradients and this diffusionsensitizing gradients which acquire MR signals, are the real good contrast DW images because of the diffusion of water protons Aydin et al, 2012a;Koh et al, 2007;Le Bihan et al, 1988). The MR signal obtained by diffusion-sensitizing gradients are equated by: S (b) = So -(bxADC) , S (b) is the measured diffusion signal, So is the signal intensity without diffusion, b is the b-value (sec/mm 2 ) for determining the magnitude, duration and time between the pair of gradients and ADC of water molecules Aydin et al, 2012a;Koh et al, 2007).…”
Section: General Knowledge About Current Dwi Techniquementioning
confidence: 99%
“…In general, Rapidly growing tumors are characterized by increased tissue cellularity and cellular density with the increased amount of diffusion barriers, the motion of diffusion capacity is restricted and water diffuses from extracellular components to the intracellular space, resulting to low ADC values and high signal intensity on DWI, however high ADC values are attributed to the free motion of water molecules in fluid-rich biologic environments (Thomas et al, 2012;Shinya et al, 2009;Aydin et al, 2012a;Aydin et al, 2012b;Wang et al, 2011;Takeuchi et al, 2008;Ichikawa et al, 2007). DWI is influenced by both water diffusion and T2 relaxation time(T2-shinethrough effect) which is the non-pure ADC maps of DW images, containing mixed contributions from T2 effects and spin-density phenomenon, leading to high signal appearing simple cysts on DWI with b value 0 sec/mm 2 , low signal intensity on high-b value images and high signal intensity on ADC maps, but however hyper intensity of abscesses, hydatid cysts and neoplastic cysts on 1000 sec/mm images with adequate SNR so multiple excitations with applied three dimensional gradients allow accurate images with good SNR for multiplanar reconstruction Koh et al, 2007, Aydin, 2012cIchikawa et al, 2007;Le Bihan et al, 1988;Takahara et al, 2004).…”
Section: General Knowledge About Current Dwi Techniquementioning
confidence: 99%
See 3 more Smart Citations