1984
DOI: 10.1016/s0001-2998(84)80005-7
|View full text |Cite
|
Sign up to set email alerts
|

The role of gallium-67 in the clinical evaluation of cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
28
0
2

Year Published

1988
1988
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 97 publications
(31 citation statements)
references
References 109 publications
1
28
0
2
Order By: Relevance
“…Despite its established role in the evaluation of high-grade NHL and HD, the sensitivity of Ga-67 scintigraphy is limited with its lower resolution limits in tumors smaller than 2 cm. 30 Single positron emission computed tomography images provide cross-sectional images and hence have higher resolution and sensitivity for lesion detection than planar images. 31 In our series, Ga-67 SPECT missed 35.7% of the lesions (Table 1).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite its established role in the evaluation of high-grade NHL and HD, the sensitivity of Ga-67 scintigraphy is limited with its lower resolution limits in tumors smaller than 2 cm. 30 Single positron emission computed tomography images provide cross-sectional images and hence have higher resolution and sensitivity for lesion detection than planar images. 31 In our series, Ga-67 SPECT missed 35.7% of the lesions (Table 1).…”
Section: Discussionmentioning
confidence: 99%
“…5,[7][8][9][10][11] It is widely accepted that Ga-67 is an indicator of tumor viability, notwithstanding that its sensitivity is highly dependent on the cell type and the size and the location of the lesion. 12 Ga-67 is more sensitive in Hodgkin disease (HD) and aggressive lymphomas than in lowgrade lymphoma for lesions of greater than 2 cm in dimension, and in the mediastinum. It is often difficult to differentiate possible disease sites from physiologic uptake in the abdomen with Ga-67 scintigraphy; thus, the sensitivity and specificity of this technique are low for tumors located in the abdomen.…”
mentioning
confidence: 99%
“…En iyi hedef/zemin aktivite oranına 48-72 saatte ulaşılır. Düşük özgüllüğü yanında, uzun fiziksel yarı ömrü, yüksek enerjili gama ışını, görüntülemede dezavantajları olup hasta ile personel yüksek radyasyon dozuna maruz kalır (22,23). Tanısal doğruluğu %60-80 civarındadır (1).…”
Section: Ga-67sitratunclassified
“…Ga) has been used for the detection of various tumors 1,2) and acute and chronic inflammations, 3,4) since the first observation of its accumulation in tumors 5) and inflammatory lesions. 6,7) Moreover, in chronic hepatitis C, it was reported that there was more accumulation in the liver in patients with chronic persistent hepatitis than in those with cirrhosis.…”
mentioning
confidence: 99%