2019
DOI: 10.1051/epjconf/201921902004
|View full text |Cite
|
Sign up to set email alerts
|

The pulsed neutron beam EDM experiment

Abstract: We report on the Beam EDM experiment, which aims to employ a pulsed cold neutron beam to search for an electric dipole moment instead of the established use of storable ultracold neutrons. We present a brief overview of the basic measurement concept and the current status of our proof-of-principle Ramsey apparatus.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…The blue shaded region represents a typical future prospect for the neutron EDM searches: 2 -3 × 10 −15 e fm by nEDM@SNS [148], 3 × 10 −14 e fm by nEDM search at LANL [149], O(10 −14 )e fm by TUCAN [150], O(10 −14 )e fm by PanEDM [151], O(10 −(14 -15) )e fm by PNPI-ILL-PTI [152], O(10 −(14 -15) )e fm by n2EDM [153] (see also Ref. [154] for beam EDM experiments). Thus, we can obtain information on relatively high scale SUSY, where the soft mass is of the order of 0.1 -1 PeV, depending on y D and N .…”
Section: Summary Plotsmentioning
confidence: 94%
See 1 more Smart Citation
“…The blue shaded region represents a typical future prospect for the neutron EDM searches: 2 -3 × 10 −15 e fm by nEDM@SNS [148], 3 × 10 −14 e fm by nEDM search at LANL [149], O(10 −14 )e fm by TUCAN [150], O(10 −14 )e fm by PanEDM [151], O(10 −(14 -15) )e fm by PNPI-ILL-PTI [152], O(10 −(14 -15) )e fm by n2EDM [153] (see also Ref. [154] for beam EDM experiments). Thus, we can obtain information on relatively high scale SUSY, where the soft mass is of the order of 0.1 -1 PeV, depending on y D and N .…”
Section: Summary Plotsmentioning
confidence: 94%
“…The red-shaded region is excluded from the current constraint on θ [147]. The blue shaded region represents the typical sensitivity of future experiments [148][149][150][151][152][153][154].…”
Section: Summary Plotsmentioning
confidence: 99%
“…The idea of beam experiments has also been revisited: the spurious effect of the motional field could be utilized to extract the EDM signal in conjunction with the pulsed structure of the cold neutron beam at a spallation source [130,152]. Modular units of vacuum chambers containing precision field plates could be assembled together to lengthen the free precession region to tens and hundreds of meters.…”
Section: Statisticalmentioning
confidence: 99%
“…[ 32 ] Name Lab Technique Ref. nEDM@SNS Oak ridge - Spallation source UCN - superfluid helium - He comagnetometer [ 43 ] n2EDM PSI - Spallation source UCN - double chamber - Hg comagnetometer [ 41 ] nEDM@LANL LANL - Spallation Source UCN - double chamber - Hg comagnetometer [ 39 ] TUCAN TRIUMF - Spallation Source UCN - double chamber - Hg - Xe comagnetometer [ 40 ] panEDM ILL - Reactor UCN - double chamber [ 44 ] PNPI nEDM ILL - PNPI UCN - double chamber [ 38 ] beam nEDM ESS spallation source Pulsed cold neutron beam [ 42 ] …”
Section: Electric Dipole Momentmentioning
confidence: 99%