2019
DOI: 10.1016/j.jchromb.2019.121791
|View full text |Cite
|
Sign up to set email alerts
|

The profiling and identification of the absorbed constituents and metabolites of Naoshuantong capsule in mice biofluids and brain by ultra- fast liquid chromatography coupled with quadrupole-time-of-flight tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 26 publications
0
18
0
Order By: Relevance
“…Both negative and positive mode was set for compounds ionization. The conditions of MS detector were as described elsewhere [8]. The chromatographic separation was carried out on a Shimadzu UFLC XR instrument (Shimadzu, Kyoto, Japan) and a Phenomenex Kinetex column (2.1 mm × 100 mm, 2.6 µm, Phenomenex, CA, USA).…”
Section: Standardization Of Nstcmentioning
confidence: 99%
See 1 more Smart Citation
“…Both negative and positive mode was set for compounds ionization. The conditions of MS detector were as described elsewhere [8]. The chromatographic separation was carried out on a Shimadzu UFLC XR instrument (Shimadzu, Kyoto, Japan) and a Phenomenex Kinetex column (2.1 mm × 100 mm, 2.6 µm, Phenomenex, CA, USA).…”
Section: Standardization Of Nstcmentioning
confidence: 99%
“…Nineteen transition components of NSTC (9 prototype components and 10 metabolites) that had been detected in the brain in the previous study [8] were used for screening potential targets. Details of their chemical structures and information were shown in supplementary material Fig.…”
Section: Data Preparation and Target Predictionmentioning
confidence: 99%
“…The conditions of MS detector were as described elsewhere [8]. The chromatographic separation was carried out on a Shimadzu UFLC XR instrument (Shimadzu, Kyoto, Japan) and a Phenomenex Kinetex column (2.1mm ×100mm, 2.6μm, Phenomenex, CA, USA).…”
Section: Standardization Of Nstcmentioning
confidence: 99%
“…Nineteen transition components of NSTC (9 prototype components and 10 metabolites) that had been detected in the brain in the previous study [8] were used for screening potential targets. Details of their chemical structures and information were shown in supplementary material Figure 1 and supplementary material Table 1 respectively.…”
Section: Data Preparation and Target Predictionmentioning
confidence: 99%
See 1 more Smart Citation