2020
DOI: 10.1088/1742-6596/1660/1/012093
|View full text |Cite
|
Sign up to set email alerts
|

The Preparing and Characterization of Nanocomposite (PTh/SWCNT) for NO2 Gas Sensing

Abstract: We prepared polythiophene (PTH) with single wall carbon nanotube (SWCNT) nanocomposite thin films for Nitrogen dioxide (NO2) gas sensing applications. Thin films were synthesized via electrochemical polymerization method onto (Indium tin oxide) ITO coated glass substrate of thiophene monomer with magnesium perchlorate and different concentration from SWCNT (0.012 and 0.016) % in the presence130mL of Acetonitrile used. X-ray diffraction (XRD), Field Emission Scanning Electron microscopy (FE-SEM), Atomic Force M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…42 Interdigitated aluminum ohmic metal contacts are deposited on the 4i lms by the thermal evaporation technique to fabricate the gas sensor. 43 The experimental setup prepared for the gas sensor testing system is suitable to determine the sensitivity parameter mainly the response time and recovery time of the fabricated 4i gas sensor detector. It consists of a cylindrical stainless-steel test chamber with an effective volume of 2649 cm 3 , and it has an inlet for permitting the tested gas to ow in and an air admittance valve to permit the ow of atmospheric air aer evacuation.…”
Section: Sensor Testingmentioning
confidence: 99%
See 1 more Smart Citation
“…42 Interdigitated aluminum ohmic metal contacts are deposited on the 4i lms by the thermal evaporation technique to fabricate the gas sensor. 43 The experimental setup prepared for the gas sensor testing system is suitable to determine the sensitivity parameter mainly the response time and recovery time of the fabricated 4i gas sensor detector. It consists of a cylindrical stainless-steel test chamber with an effective volume of 2649 cm 3 , and it has an inlet for permitting the tested gas to ow in and an air admittance valve to permit the ow of atmospheric air aer evacuation.…”
Section: Sensor Testingmentioning
confidence: 99%
“…Interdigitated aluminum ohmic metal contacts are deposited on the 4i films by the thermal evaporation technique to fabricate the gas sensor. 43 …”
Section: Materials and Synthesismentioning
confidence: 99%