1998
DOI: 10.1039/a805387a
|View full text |Cite
|
Sign up to set email alerts
|

The potential of a modified rf glow discharge source for enhanced elemental speciation studies

Abstract: Radio frequency glow discharge source mass spectrometry (rf GDMS) was employed for determination of tetramethyltin (TMT) with axial sample introduction via capillary gas chromatography (GC). The axial cell design provided homogenous sampling independent of the transfer line capillary position by eliminating discharge asymmetry. Sensitivity value for TMT of 2237 counts pg 21 was achieved with the current setup, a nearly three-fold improvement from a previous study (681 counts pg 21 ). The 120 Sn + ion signal in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
12
0

Year Published

2000
2000
2006
2006

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 26 publications
(26 reference statements)
0
12
0
Order By: Relevance
“…Due to the relatively large sampler ori ce, the pressure measured in the expansion stage of the m ass spectrometer was considered to be a good estimate of the cell pressure for the LP/RP-ICP, as in previous studies. 4,11,12 G C-LP/RP-ICP Interface. A diagram of the interface has been shown in detail in previous studies.…”
Section: Experim Entalmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the relatively large sampler ori ce, the pressure measured in the expansion stage of the m ass spectrometer was considered to be a good estimate of the cell pressure for the LP/RP-ICP, as in previous studies. 4,11,12 G C-LP/RP-ICP Interface. A diagram of the interface has been shown in detail in previous studies.…”
Section: Experim Entalmentioning
confidence: 99%
“…This pressure was used to collect mass spectral data in the time-resolved data acquisition m ode (TRA). Table I lists 12 In the current study, pressure was varied for an LP/RP-ICP cell, and the effects on the fragm entation of TET were obser ved. Figure 1 shows that the intensities of the fragm ent ions, relative to the elemental ion for TET for the He LP/ RP-ICP, are greater at lower pressures, thus illustrating a trend similar to that found by Belkin et al 12 The sensitivity at these lower pressures, however, is slightly worse for the elemental ion as well as for the fragment ions.…”
Section: Experim Entalmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the late 1980s attention has been given to developing the glow discharge for the analysis of organic compounds 2–14. Glow discharge sources have been used as element‐specific detectors for gas chromatography (GC), with particular emphasis on applications in speciation studies 15.…”
mentioning
confidence: 99%
“…The ionizing capabilities of the glow discharge lies between these two extremes of conventional atomic and molecular ion sources. The number of papers describing the glow discharge as an element‐specific detector for GC is small by comparison to ICP‐MS; however, it does show promise as a ‘tuneable’ plasma source,17 and has been investigated by a number of groups 4–14. The discharge conditions (i.e.…”
mentioning