2014
DOI: 10.1016/j.radphyschem.2013.04.035
|View full text |Cite
|
Sign up to set email alerts
|

The physical characteristics of the 15MV Varian Clinac 2100C unflattened beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…1a, where the main details relevant to the electron beam transport simulation as implemented in the Monte Carlo MCNPX geometry of the LINAC are described. The geometry aims at approximately describe the Varian Truebeam Stx© starting from the Varian Clinac©2100 model description freely obtained from the scientific literature (Najem et al, 2014;Ovalle, 2013;Nedaje et al, 2015;Bezoubiri et al, 2014). The presence of a lead cake has also been considered on the basis of functional needs.…”
Section: The Bunker Geometry the Treatment Room And The Measurement S...mentioning
confidence: 99%
“…1a, where the main details relevant to the electron beam transport simulation as implemented in the Monte Carlo MCNPX geometry of the LINAC are described. The geometry aims at approximately describe the Varian Truebeam Stx© starting from the Varian Clinac©2100 model description freely obtained from the scientific literature (Najem et al, 2014;Ovalle, 2013;Nedaje et al, 2015;Bezoubiri et al, 2014). The presence of a lead cake has also been considered on the basis of functional needs.…”
Section: The Bunker Geometry the Treatment Room And The Measurement S...mentioning
confidence: 99%
“…Several studies have reported the concept of freeflattening filter (FFF) beams at various energies [6,7]. The removal of the FF has been reported to decrease head scatter and increase the dose rate [8,9], as well as reduce electron and neutron contamination [10,11], penumbra, and out-of-field doses [6,12]. The presence of contaminant particles in the FF beam stems from the interaction of bremsstrahlung photons from the x-ray target with electrons and nuclei of the copper, resulting in particle contamination (electrons and neutrons) beyond the FF [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…Several studies related to flattening filter free (FFF) have been conducted at different energies [10,11]. They reported that removing the FF increased the dose rate and reduce the head scatter [12][13][14], electrons and neutrons contamination [15,16], out-of-field and penumbra doses [11,17,18]. The increase in particle contaminants in the FFF beam is caused by the bremsstrahlung photon from the X-ray target interacting with the electrons and nucleus of Cu and producing particle contamination (electron and neutron) after the FF [15,16].…”
Section: Introduction mentioning
confidence: 99%