2009
DOI: 10.1016/j.ejpb.2008.09.006
|View full text |Cite
|
Sign up to set email alerts
|

The permeability of large molecular weight solutes following particle delivery to air-interfaced cells that model the respiratory mucosa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
72
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 77 publications
(74 citation statements)
references
References 20 publications
2
72
0
Order By: Relevance
“…Deposition of particles generated by each formulation onto the cell layers and measurement of transepithelial BDP flux was conducted using methods adapted from Grainger et al [10,17]. In this method, the twin stage impinger (TSI) (Radleys, Essex, UK) was modified to accommodate a Transwell insert in the lower chamber.…”
Section: In Vitro Cell Deposition Studiesmentioning
confidence: 99%
“…Deposition of particles generated by each formulation onto the cell layers and measurement of transepithelial BDP flux was conducted using methods adapted from Grainger et al [10,17]. In this method, the twin stage impinger (TSI) (Radleys, Essex, UK) was modified to accommodate a Transwell insert in the lower chamber.…”
Section: In Vitro Cell Deposition Studiesmentioning
confidence: 99%
“…Whilst particle cutoff diameter and regional lung deposition are not precise, in an anatomical sense, these pharmacopeia approaches still give some indication of regional lung deposition. Prior to testing, 7 mL of water was added to stage 1 of the TSI and stage 2 was modified as described previously to accommodate a Transwell assembly (19). The TSI was adjusted to a flow rate of 60 L min −1 using a rotary vein pump and solenoid timer (Copley Scientific, Nottingham, UK) in combination with a calibrated flow meter (TSI, 4000 series, Buckinghamshire, UK) to which an Aerolizer® DPI device (Novartis, Surrey, UK) was attached to the inlet of the flow meter to account for the pressure drop across the device.…”
Section: Physicochemical Characterisation Of the Dscg And Dscg/pva MImentioning
confidence: 99%
“…The aerosolisation and deposition of drug onto the air interface model was conducted in a similar manner to the TSI studies described previously (19). Briefly, the method followed that of Grainger et al, where the TSI was modified to incorporate the Transwell insert at the stage 2 jet assembly (no liquid was added to stage 2).…”
Section: Drug Aerosol Deposition and Uptake Studiesmentioning
confidence: 99%
See 2 more Smart Citations