The new PTB angle comparator

Abstract: A new highly precise angle measuring table has been developed for the Physikalisch-Technische Bundesanstalt, which is to be used as a comparator to calibrate angle standards. First results of the determination of the comparator's errors of measurement obtained by two calibration methods are reported. Considering the results obtained, it is to be expected that the desired uncertainty of measurement of can be achieved.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
91
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 106 publications
(97 citation statements)
references
References 0 publications
0
91
0
Order By: Relevance
“…The In order to realize the stage's potential for calibration of profilometers, a high accuracy angular calibration of the stage is required. We have described an experimental method that allows us to have the tilting stage traceable back to the PTB high performance angle comparator WMT 220 34,35 via application of the AC calibrated at the PTB.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The In order to realize the stage's potential for calibration of profilometers, a high accuracy angular calibration of the stage is required. We have described an experimental method that allows us to have the tilting stage traceable back to the PTB high performance angle comparator WMT 220 34,35 via application of the AC calibrated at the PTB.…”
Section: Discussionmentioning
confidence: 99%
“…17˗19,24,37,39,40,43 The autocollimators are initially calibrated at the PTB using their Heidenhain TM WMT 220 angle comparator. 34,35 The angle comparator utilizes subdivision of a full circle enclosure, which removes the need for an outside angular reference, to establish an angular standard. The ultimate standard measurement uncertainty of the WMT 220 is about 5 nrad.…”
Section: Utm Tilt Stage Characterization With An Autocollimatormentioning
confidence: 99%
See 1 more Smart Citation
“…At the PTB, autocollimator calibration is realized by its direct comparison to the primary angle standard, the Heidenhain WMT 220 angle comparator, manufactured by Dr. Johannes Heidenhain GmbH, Traunreut, Germany [26]. With the aid of various selfand cross-calibration techniques, the standard measurement uncertainty [27] of the WMT 220 could be reduced to u = 0.001 arcsec (5 nrad) [28,29].…”
Section: Autocollimator Calibration Datamentioning
confidence: 99%
“…the reliability of the instrument readings is not guaranteed at the same level. Indeed today only in exceptionally complex and accurate facilities operating in few National Metrology Institutes in the world can provide angle measurements/calibrations with nanoradian level accuracy [1,2]. The European project "Angles" [3] is devoted to develop instruments methods and guidelines to improve the accuracy of angle measurements in various application field.…”
Section: Introductionmentioning
confidence: 99%