The M. D. Anderson proton therapy system

Abstract: As with most projects for which a considerable amount of new technology is developed and which have duration spanning several years, at project completion it was determined that several upgrades would improve the overall system performance. Some possible upgrades are discussed. Overall, the system has been very robust, accurate, reproducible, and reliable. The authors found the pencil beam scanning system to be particularly satisfactory; prostate treatments can be delivered on the scanning nozzle in less time … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
154
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 170 publications
(162 citation statements)
references
References 18 publications
3
154
0
1
Order By: Relevance
“…Nevertheless, one of the limitation of this study is that the beam delivery time is estimated based on a single room system, as a result the room switching time and waiting time from a multiroom proton center were not estimated. Hence, additional time is needed to be added to compensate the difference between the single room and multiroom system system 16. In a busy multiroom center, IMPT with eight beam angles might still not be practically feasible due to the long waiting time.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, one of the limitation of this study is that the beam delivery time is estimated based on a single room system, as a result the room switching time and waiting time from a multiroom proton center were not estimated. Hence, additional time is needed to be added to compensate the difference between the single room and multiroom system system 16. In a busy multiroom center, IMPT with eight beam angles might still not be practically feasible due to the long waiting time.…”
Section: Discussionmentioning
confidence: 99%
“…Technical details of the proton therapy system used in this report have been described in a previous report (26) . The components along the beam path (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The Hitachi delivery system contains helium chambers at the beam pass (6,7,9). To minimize beam scattering in air, a vacuum inside the nozzle is assumed.…”
Section: Beam Nozzle Layout Modelsmentioning
confidence: 99%
“…The characteristics of the beam entering the nozzle were set to mimic currently achievable beam parameters (7,9,10,16). …”
Section: Proton Beam Characterizationmentioning
confidence: 99%
See 1 more Smart Citation