Redefine the role of range shifter in treating bilateral head and neck cancer in the era of Intensity Modulated Proton Therapy

Search citation statements

Order By: Relevance

Paper Sections

Select...
7
4
4
1

Citation Types

0
22
0
0

Year Published

2019
2019
2026
2026

Publication Types

Select...
14

Relationship

7
7

Authors

Journals

citations

Cited by 14 publications

(22 citation statements)
references

References 18 publications

0
22
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…31 Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter. 32 The delivery time estimation showed auto beam sequencing delivery of static PAT plans and delivery of dynamic PAT plans is expected to be faster than current clinical IMPT delivery. IMPT delivery time could be reduced by approximately 2 min when automatic beam sequencing is available.…”
Section: Discussion
mentioning
confidence: 99%
“… 31 Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter. 32 …”
Section: Discussion
mentioning
confidence: 99%
“…PAT NTCP could also be further reduced by reducing the uncertainty settings for robust optimization 31 . Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter 32 …”
Section: Discussion
mentioning
confidence: 99%
See 2 more Smart Citations
How this paper cites the one you are viewing
“…31 Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter. 32 The delivery time estimation showed auto beam sequencing delivery of static PAT plans and delivery of dynamic PAT plans is expected to be faster than current clinical IMPT delivery. IMPT delivery time could be reduced by approximately 2 min when automatic beam sequencing is available.…”
Section: Discussion
mentioning
confidence: 99%
“… 31 Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter. 32 …”
Section: Discussion
mentioning
confidence: 99%
“…PAT NTCP could also be further reduced by reducing the uncertainty settings for robust optimization 31 . Furthermore, the use of range shifters in the IMPT beams could be omitted, which avoids increased spot size caused by proton scatter in the range shifter 32 …”
Section: Discussion
mentioning
confidence: 99%
See 1 more Smart Citation
How this paper cites the one you are viewing
“…This, however, introduces a potential risk of gantry-patient collision. Consequently, these drawbacks become more pronounced when treating tumors with complex surrounding anatomical structures, such as bilateral head and neck tumors or skull base tumors ( 30 ). For breast cancer, however, our statistics on the minimum air gap indicated that the use of RS does not significantly reduce the air gap between the treatment head and the patient.…”
Section: Discussion
mentioning
confidence: 99%
How this paper cites the one you are viewing
“…Dosimetric improvements could potentially improve the treatment outcome by reducing acute and late toxicities. Recent studies have shown improved IMPT robustness associated with the increase of treatment fields while decreasing OARs sparing [12,30,31]. However, such approaches using numerous static beam angles were considered impractical due to the prolonged treatment delivery time, especially in a multi-room proton center where significant time will be spent in the room-switching time/waiting time [32].…”
Section: Discussion
mentioning
confidence: 99%