The Long-Term Drift of Triple-Point-of-Water Cells

Abstract: As the triple point of water is of great importance for the International Temperature Scale of 1990 (ITS-90) and for the definition of the unit of thermodynamic temperature, its long-term stability has attracted a great deal of attention. In a study of long-term stability, a mystery has been uncovered. Some triple-point-ofwater cells remain stable for many decades, while others decrease with increasing age of the cells, which is called long-term drift. To investigate this mystery, we used cells with different … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…However, there are errors and uncertainties associated with the practical realization of the triple point, all of which are summarised in detail in [55]. Because the cell was manufactured without an isotopic analysis, and chemical analysis would require the destruction of the cell, the temperature realized in the cell was determined by comparing it to the NIM standard TPW cell [56,57] with a long-stem standard platinum resistance thermometer (SPRT). The temperature realized in the cell was found to be 1.46 mK higher than that in the NIM standard cell.…”
Section: Qvns Waveformmentioning
confidence: 99%
“…However, there are errors and uncertainties associated with the practical realization of the triple point, all of which are summarised in detail in [55]. Because the cell was manufactured without an isotopic analysis, and chemical analysis would require the destruction of the cell, the temperature realized in the cell was determined by comparing it to the NIM standard TPW cell [56,57] with a long-stem standard platinum resistance thermometer (SPRT). The temperature realized in the cell was found to be 1.46 mK higher than that in the NIM standard cell.…”
Section: Qvns Waveformmentioning
confidence: 99%
“…In addition, since gaseous impurities also tend to have some finite solubility in water, they may affect the realized TPW temperature in the same manner as the impurities present in the water due to dissolution of the glass. It was reported during regular TPW intercomparisons [4][5][6] that accumulation of residual gases in several sealed TPW cells decreased the realized TPW temperature by more than 100 μK.…”
Section: Old Borosilicate Triple-point-of-water Cells: Issuesmentioning
confidence: 99%
“…Thus, throughout the temperature measurements, a TPW cell is used multiple times in order to: (a) assess the stability of the SPRT as part of a regular check-up procedure and (b) calculate W(T 90 ) using TPW measurements made immediately after the measurement at T 90 (or made with the SPRT in the same oxidation state) [3]. Consequently, temperature metrology labs all around the world typically maintain a stock of several TPW cells which is checked on a regular basis [4][5][6][7]. At the national level, an ensemble of several carefully chosen TPW cells in a National Metrology Institute (NMI) forms the national standard for the TPW temperature [8].…”
Section: Introductionmentioning
confidence: 99%