The intra- and inter-examiner reliability of quantitative light-induced fluorescence (QLF) analyses

Abstract: This study has demonstrated that the analysis stage of QLF is reliable between examiners and within multiple attempts by the same examiner, when analysing in vitro lesions. Novices at the technique should be trained before analysing experimental data.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
19
0
2

Year Published

2002
2002
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(22 citation statements)
references
References 1 publication
1
19
0
2
Order By: Relevance
“…The metric output of the proprietary QLF software is highly robust, following both intra-and inter-examiner reliability testing [Angmar-Mänsson and ten Bosch, 2001;Pretty et al, 2002;Tranaeus et al, 2002]. However, the decision to exclude a border is highly subjective and is based on an examiner's assessment of where the borders of the lesion can be seen, the best placement of the analysis patch and the subsequent reconstruction.…”
Section: Discussionmentioning
confidence: 99%
“…The metric output of the proprietary QLF software is highly robust, following both intra-and inter-examiner reliability testing [Angmar-Mänsson and ten Bosch, 2001;Pretty et al, 2002;Tranaeus et al, 2002]. However, the decision to exclude a border is highly subjective and is based on an examiner's assessment of where the borders of the lesion can be seen, the best placement of the analysis patch and the subsequent reconstruction.…”
Section: Discussionmentioning
confidence: 99%
“…A study performed looking at the reliability and effect of subjectivity on QLF analyses found that both intra-and inter-examiner reproducibility was high when assessing in vitro caries lesions. 18 The assessment of stain reduction is simpler, and it is reasonable to extrapolate these results to the reliability of stain assessment. Reliability can also be increased by using multiple examiners or repeated measures by the same examiner.…”
Section: Researchmentioning
confidence: 99%
“…Reliability can also be increased by using multiple examiners or repeated measures by the same examiner. 18 QLF presents an expeditious, user-friendly, economical and resilient method of assessing stain reduction. The data produced can be archived and the ability to blind examiners and conduct repeated analysis of the images strengthens studies employing QLF.…”
Section: Researchmentioning
confidence: 99%
“…A ocorrência de cáries resulta em aumento da quantidade de água na estrutura, e também no aumento do coeficiente de espalhamento da luz na região da lesão em relação ao tecido sadio (PRETTY et al, 2002). O coeficiente de espalhamento aumentado causa a diminuição da fluorescência predominantemente devido ao bloqueio da fluorescência originária da dentina e da junção amelo-dentinária (DE JOSSELIN DE JONG et al, 1995;TRANAEUS et al, 2002).…”
Section: Quantificação Da Fluorescência Induzida Por Luz (Qlf)unclassified
“…Além disso, as imagens e as mensurações de todos os grupos foram realizadas por um único operador cego quanto aos grupos em estudo e treinado para a realização das avaliações segundo os padrões sugeridos por Pretty e colaboradores (PRETTY et al, 2002). Essas medidas foram tomadas para se reduzir a probabilidade de viés (bias) do operador durante as avaliações e também garantir que as decisões subjetivas implícitas ao método fossem baseadas em padrões e regras objetivos (SPITZER;TEN BOSCH, 1977; TEN BOSCH; VAN DER MEI;BORSBOOM, 1984).…”
Section: Influência Da Duração De Pulso -Análises De Pl E Mevunclassified