2002
DOI: 10.1016/s0378-5173(02)00359-9
|View full text |Cite
|
Sign up to set email alerts
|

The influence of relative humidity on particulate interactions in carrier-based dry powder inhaler formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
85
0
1

Year Published

2005
2005
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 150 publications
(92 citation statements)
references
References 20 publications
6
85
0
1
Order By: Relevance
“…Thus, the surface of the model carrier was covered by an additional hydrophobic layer which reduced the adhesion between carrier and API particles. A similar impact was also observed for lactose and beclomethasone dipropionate particles (Young et al, 2002). Recent studies by Islam et al (2014) demonstrated the use of a salbutamol sulphate-coated model colloidal probe for comparing the adhesion between hydrophilichydrophilic and hydrophilic-hydrophobic surfaces.…”
Section: Adhesion Measurementssupporting
confidence: 54%
See 3 more Smart Citations
“…Thus, the surface of the model carrier was covered by an additional hydrophobic layer which reduced the adhesion between carrier and API particles. A similar impact was also observed for lactose and beclomethasone dipropionate particles (Young et al, 2002). Recent studies by Islam et al (2014) demonstrated the use of a salbutamol sulphate-coated model colloidal probe for comparing the adhesion between hydrophilichydrophilic and hydrophilic-hydrophobic surfaces.…”
Section: Adhesion Measurementssupporting
confidence: 54%
“…Sindel and Zimmermann (2001) for example demonstrated the deformation occurring to colloidal lactose probes when pressing them onto a lactose substrate. However, despite investigation, quantifying the impact of surface roughness and surface deformation on the force of adhesion has remained almost impossible (Cline and Dalby, 2002;Louey et al, 2001;Price et al, 2002). The accuracy of the force measurements may therefore be significantly reduced.…”
Section: Roughness and Deformationmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the significant impact of meniscus forces on the flow behavior of powders, several studies have focused on the humidity dependence of adhesion for several commercially relevant powders like hydrated alumina, a silica aerogel, limestone, titania and zeolite [702] or pharmaceutical products like a-lactose monohydrate, salbutamol sulphate, budesonide, triamcinolone acetonide, and disodium cromoglycate [634,703,704]. Duong et al [705] used force-distance curves on 900-1100 mm glass beads that were exposed to different amount of water in a shaker.…”
Section: Meniscus Forcementioning
confidence: 99%