2013
DOI: 10.1016/j.joen.2013.04.013
|View full text |Cite
|
Sign up to set email alerts
|

The Incidence of Root Microcracks Caused by 3 Different Single-file Systems versus the ProTaper System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

20
210
5
17

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 204 publications
(252 citation statements)
references
References 24 publications
20
210
5
17
Order By: Relevance
“…However, the micro-CT technology provides the possibility to examine the dentinal tissue before the root canal preparation, which is indeed a very suitable and important feature. The absence of new dentinal defects found after canal preparation with PTU system in the current study markedly contrasts with the results of previous studies, which showed that rotary canal preparation with this system could initiate and/or propagate dentinal micro-cracks (3,4,6,8,9,22). Bier and colleagues (4) observed cracks in 16% of horizontal sections of the roots instrumented with PTU system.…”
Section: Dentinal Defects and Root Canal Preparationcontrasting
confidence: 99%
See 3 more Smart Citations
“…However, the micro-CT technology provides the possibility to examine the dentinal tissue before the root canal preparation, which is indeed a very suitable and important feature. The absence of new dentinal defects found after canal preparation with PTU system in the current study markedly contrasts with the results of previous studies, which showed that rotary canal preparation with this system could initiate and/or propagate dentinal micro-cracks (3,4,6,8,9,22). Bier and colleagues (4) observed cracks in 16% of horizontal sections of the roots instrumented with PTU system.…”
Section: Dentinal Defects and Root Canal Preparationcontrasting
confidence: 99%
“…This methodology exempts the need of cutting the specimens and allows comparison of the same sample before and after instrumentation. These are the most important methodological differences regarding previous studies (4,6,8,9). The reliability of this technology to detect dentinal defects was confirmed herein, once the full extension of dentinal micro-cracks visualized under conventional stereomicroscopy was identified in the micro-CT crosssectional images.…”
Section: Discussionsupporting
confidence: 57%
See 2 more Smart Citations
“…The reciprocating movement of the instrument reduces the risk of cyclic fatigue. 11,12 In contrast, OneShape files employ traditional continuous rotation. They have a triangle-shaped cutting edge and two additional cutting edges, in the apical and coronal parts, as well as a crosssection that progressively changes from 3 to 2 cutting edges between the apical and coronal parts.…”
Section: Introductionmentioning