2021
DOI: 10.1016/j.dental.2020.09.020
|View full text |Cite
|
Sign up to set email alerts
|

The impact of different low-pressure plasma types on the physical, chemical and biological surface properties of PEEK

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
21
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 37 publications
(29 citation statements)
references
References 32 publications
1
21
0
Order By: Relevance
“…The water contact angle (WCA) measurement results are shown in Figure 7. The WCA of control material (PEEK) equaled to 74 ± 3 • , which is closed to values reported by other authors for untreated PEEK [16,17,37,38]. The modification in the presence of oxygen slightly increased the wettability of the PEEK surface, the contact angle decreased with the increase of the number of EUV pulses and amounted to 71 ± 6 • , 67 ± 10 • and 64 ± 5 • for PEEK-O 2 -100, PEEK-O 2 -150 and PEEK-O 2 -200, respectively.…”
Section: Wettabilitysupporting
confidence: 70%
See 2 more Smart Citations
“…The water contact angle (WCA) measurement results are shown in Figure 7. The WCA of control material (PEEK) equaled to 74 ± 3 • , which is closed to values reported by other authors for untreated PEEK [16,17,37,38]. The modification in the presence of oxygen slightly increased the wettability of the PEEK surface, the contact angle decreased with the increase of the number of EUV pulses and amounted to 71 ± 6 • , 67 ± 10 • and 64 ± 5 • for PEEK-O 2 -100, PEEK-O 2 -150 and PEEK-O 2 -200, respectively.…”
Section: Wettabilitysupporting
confidence: 70%
“…The value measured for PEEK-O 2 -200 was significantly lower (p < 0.05) compared to the control. Other authors also reported a decrease in WCA values for PEEK treated with plasma in the presence of oxygen [17]. PEEK modified using nitrogen gas did not show significant differences in WCA values compared to the control material.…”
Section: Wettabilitymentioning
confidence: 79%
See 1 more Smart Citation
“…17,[19][20][21] Wang et al 22 found PEEK and Variolink achieved the highest bonding strength when treated by nitrogen plasma for 25 min. Fu et al 23 demonstrated that low-pressure plasma treatments had a significant impact on the hydrophilicity, crystallinity, and thus microhardness of PEEK surfaces and caused a substantially increased adhesion property of PEEK surfaces. Among these methods, laser treatment is a promising green high-tech alternative because of its high resolution, high operating speed, plastic/metal applicability and processing flexibility.…”
Section: Introductionmentioning
confidence: 99%
“…Wang et al 22 found PEEK and Variolink achieved the highest bonding strength when treated by nitrogen plasma for 25 min. Fu et al 23 demonstrated that low‐pressure plasma treatments had a significant impact on the hydrophilicity, crystallinity, and thus microhardness of PEEK surfaces and caused a substantially increased adhesion property of PEEK surfaces.…”
Section: Introductionmentioning
confidence: 99%