1982
DOI: 10.1520/jfs12197j
|View full text |Cite
|
Sign up to set email alerts
|

The Identification of Capsaicinoids in Tear-Gas Spray

Abstract: “Natural” capsaicin has been identified in “Halt!” sprays by thin-layer chromatography (TLC), high performance liquid chromatography (HPLC), infrared spectrophotometry (IR), and gas chromatography/mass spectrometry (GC/MS). Individual capsaicinoids have been identified as capsaicin, dihydrocapsaicin, and nordihydrocapsaicin. The recommended analytical procedure for small samples is HPLC followed by GC/MS. The alternative procedure of solvent extraction and preparation TLC followed by IR is recommended for larg… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
9
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 7 publications
1
9
0
Order By: Relevance
“…b No P450 spectrum was detected in the sample. exchange LC/MS/MS and was consistent with previous MS/MS and MS 3 studies of capsaicin (15,48). Identical fragmentation patterns were observed for nonivamide and dihydrocapsaicin (the saturated analogue of capsaicin); however, the m/z values for the product ions, derived from the alkyl portion of the molecules, were 12 amu less or 2 amu greater than capsaicin, respectively (data not shown).…”
Section: Identification Of Metabolites By Lc/ms Lc/ms/ Ms and Lc/nmrsupporting
confidence: 89%
See 1 more Smart Citation
“…b No P450 spectrum was detected in the sample. exchange LC/MS/MS and was consistent with previous MS/MS and MS 3 studies of capsaicin (15,48). Identical fragmentation patterns were observed for nonivamide and dihydrocapsaicin (the saturated analogue of capsaicin); however, the m/z values for the product ions, derived from the alkyl portion of the molecules, were 12 amu less or 2 amu greater than capsaicin, respectively (data not shown).…”
Section: Identification Of Metabolites By Lc/ms Lc/ms/ Ms and Lc/nmrsupporting
confidence: 89%
“…The chemical shifts for the carbon atoms and protons in Table 2 were achieved using DQCOSY and TOCSY, while the carbon shifts were obtained by HSQC and HMBC data. In the HMBC spectrum (Figure 8), the six methyl protons on C 17 exhibited coupling to itself (gemdimethyl; 28.9 ppm), the quaternary carbon at C 16 (71.2 ppm), as well as coupling to C 15 (137.8 ppm). Similarly, the olefinic protons (14 and 15) exhibited correlations with C 16 and C 17 , while C 14 (127.5 ppm) was correlated to the number 12 protons.…”
Section: Identification Of Metabolites By Lc/ms Lc/ms/ Ms and Lc/nmrmentioning
confidence: 99%
“…The main active ingredient in most pepper sprays is oleoresin capsicum, which is the oily extract of hot peppers [7][8][10][11][12]. Although oleoresin capsicum is composed of several capsaicinoids, capsaicin is the most abundant and thus the most appealing for analytical purposes [7][8][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Several minor capsaicinoids and related compounds have also been identified (Maillard, Giampaoli, & Richard, 1997;Schweiggert, Carle, & Schieber, 2006;Thompson, Phinney, Sander, & Welch, 2005), but are present at very low levels and not expected to contribute greatly to overall pungency (Krajewska & Powers, 1988;Todd & Bensinger, 1977). Apart from their role as flavor ingredients, medical, toxicological and repellent applications of these compounds have also been described (Fung, Jeffery, & Beveridge, 1982;Reilly et al, 2005;Yosipovitch, Mengesha, Facliaru, & David, 1982).…”
Section: Introductionmentioning
confidence: 99%