2014
DOI: 10.1016/j.jelechem.2014.07.036
|View full text |Cite
|
Sign up to set email alerts
|

The fabrication of a Co (II) complex and multi-walled carbon nanotubes modified glass carbon electrode, and its application for the determination of dopamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
4
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(5 citation statements)
references
References 35 publications
1
4
0
Order By: Relevance
“…On the other hand, the selection of more positive potentials at the region of plateau of current for all phenolic compounds, which is a common practice when a hydrodynamic method (under stirring or flow rate) with amperometric detection is used, revealed that the use of MWCNT-modified electrodes may not be essential for the determination of HQ, TBHQ, CT, and DP because the gain in sensitivity and linear range is not so significant (10 to 40%). The limit of detection values obtained under both amperometric conditions on the SD-MWCNT-modified GCE were estimated as 0.03 (for DP), 0.17 (for CT and HQ) and 0.33 mmol L À1 (for TBHQ), which are within the values verified by previous works using modified electrodes containing CNTs or composites formed by CNTs and other chemical modifiers applied for DP (0.015-1.76 mmol L À1 ) [37,38,[41][42][43][44][45], CT (0.095-2.0 mmol L À1 ) [39,40,[47][48][49][50], HQ (0.02-2.6 mmol L À1 ) [46][47][48][49][50], and TBHQ (0.067-5.0 mmol L À1 ) [51][52][53][54].…”
Section: Electrochemical Measurementssupporting
confidence: 83%
“…On the other hand, the selection of more positive potentials at the region of plateau of current for all phenolic compounds, which is a common practice when a hydrodynamic method (under stirring or flow rate) with amperometric detection is used, revealed that the use of MWCNT-modified electrodes may not be essential for the determination of HQ, TBHQ, CT, and DP because the gain in sensitivity and linear range is not so significant (10 to 40%). The limit of detection values obtained under both amperometric conditions on the SD-MWCNT-modified GCE were estimated as 0.03 (for DP), 0.17 (for CT and HQ) and 0.33 mmol L À1 (for TBHQ), which are within the values verified by previous works using modified electrodes containing CNTs or composites formed by CNTs and other chemical modifiers applied for DP (0.015-1.76 mmol L À1 ) [37,38,[41][42][43][44][45], CT (0.095-2.0 mmol L À1 ) [39,40,[47][48][49][50], HQ (0.02-2.6 mmol L À1 ) [46][47][48][49][50], and TBHQ (0.067-5.0 mmol L À1 ) [51][52][53][54].…”
Section: Electrochemical Measurementssupporting
confidence: 83%
“…To obtain more insight into the adsorptive properties of 4 , we deposited 4 on the GC electrode covered by multi-walled carbon nanotubes (MWCNT). Various macrocyclic compounds have been previously deposited on the surface of MWCNT in order to construct electrocatalytic sensors [ 45 , 46 , 47 , 48 ]. The resultant GC/MWCNT/ 4 was investigated using CV in an aqueous 0.1 M HClO 4 electrolyte ( Figure 8 ).…”
Section: Resultsmentioning
confidence: 99%
“…Dopamine (DA) is a naturally occurring catecholamine that plays crucial role in the function of cardiovascular, central nervous, renal and hormonal systems and its anomalous concentration cause numerous problems like Parkinson's disease, neurological disorder, drug addiction and Schizophrenia [1][2][3][4][5][6][7]. Therefore, searching an appropriate method for sensitive determination of DA is of great importance in the biological diagnosis.…”
Section: Introductionmentioning
confidence: 99%
“…Different pervious works have been reported for determination of DA. To mention some of them: chromatography [8,9], spectrophotometry [10][11][12], fluorescence [13], chemiluminescence [14,15], and electroanalysis [1][2][3][4][5][6][16][17][18][19]. Electrochemical techniques have attracted great concern over other analytical methods as the analysis is fast, low in cost, high accuracy and low detection limit [1][2][3][4][5][6][7]20].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation